Gunther tulip filter: Preliminary clinical experience with retrieval

被引:60
作者
Millward, SF
Bhargava, A
Aquino, J
Peterson, RA
Veinot, JP
Bormanis, J
Wells, PS
机构
[1] Univ Ottawa, Ottawa Civic Hosp, Dept Diagnost Imaging, Ottawa, ON K1Y 4E9, Canada
[2] Univ Ottawa, Ottawa Civic Hosp, Dept Med, Ottawa, ON K1Y 4E9, Canada
[3] Univ Ottawa, Ottawa Civic Hosp, Div Anat Pathol, Ottawa, ON K1Y 4E9, Canada
关键词
embolism; pulmonary; thrombosis; venous; venae cavae; filters;
D O I
10.1016/S1051-0443(07)61286-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The Gunther Tulip filter is a permanent filter that has a hook to permit retrieval. The authors report their preliminary clinical evaluation of the filter with regard to feasibility and safety of retrieval, MATERIALS AND METHODS: Nine men and six women who ranged in age from 17 to 79 years (mean, 51 years) underwent treatment with use of the Gunther Tulip filter. Patients judged to require caval interruption for <14 days were selected to receive the filter and retrieval was planned for all patients. Indications for filter placement were: recent pulmonary embolism (PE) or proximal deep vein thrombosis (DVT) with a contraindication to anticoagulation (11 patients), massive PE treated with thrombolytic therapy (one patient), PE with heparin-induced thrombocytopenia (one patient), and prophylaxis after major trauma (two patients), Patients were followed for inferior vena cava (IVC) thrombosis, bleeding, and recurrent DVT or PE. RESULTS: In all nine patients in whom it was attempted, the filter was successfully snared and retrieved via a jugular approach. The mean implantation period was 8.6 days (range, 5-13 days), Retrieval required 2.2-13 minutes (mean 5.3 minutes) of fluoroscopy, No caval injuries occurred as a result of retrieval. All retrieved filters had strands of organized thrombus on the filter struts. The patients were followed for 52-285 days (mean, 115 days) after retrieval. One patient developed a recurrent DVT 230 days after retrieval, No other patients developed a recurrent DVT and no patients developed IVC thrombosis, bleeding, or PE, Six filters were not retrieved: five because of an ongoing contraindication to anticoagulation and one because the patient died of causes unrelated to the filter. CONCLUSION: This preliminary study confirms the feasibility and safety of retrieval of the Gunther Tulip filter up to 13 days after implantation.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 20 条
[1]  
ABBOTT GT, 1999, J VASC INTERV RADIOL, V10, P288
[2]   COMPLICATIONS OF VENA-CAVA FILTERS [J].
ATHANASOULIS, CA .
RADIOLOGY, 1993, 188 (03) :614-615
[3]   INFERIOR VENA-CAVA FILTERS - INDICATIONS, SAFETY, EFFECTIVENESS [J].
BECKER, DM ;
PHILBRICK, JT ;
SELBY, JB .
ARCHIVES OF INTERNAL MEDICINE, 1992, 152 (10) :1985-1994
[4]   The Tempofilter((R)): A multicenter study of a new temporary caval filter implantable for up to six weeks [J].
Bovyn, G ;
Gory, P ;
Reynaud, P ;
Ricco, JB .
ANNALS OF VASCULAR SURGERY, 1997, 11 (05) :520-528
[5]   Temporary use of a Bird's Nest filter during iliocaval thrombolysis [J].
Cope, C ;
Baum, RA ;
Duszak, RA .
RADIOLOGY, 1996, 198 (03) :765-767
[6]   VENA TECH-LGM FILTER - LONG-TERM RESULTS OF A PROSPECTIVE-STUDY [J].
CROCHET, DP ;
STORA, O ;
FERRY, D ;
GROSSETETE, R ;
LEURENT, B ;
BRUNEL, P ;
NGUYEN, JM .
RADIOLOGY, 1993, 188 (03) :857-860
[7]   A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis [J].
Decousus, H ;
Leizorovicz, A ;
Parent, F ;
Page, Y ;
Tardy, B ;
Girard, P ;
Laporte, S ;
Faivre, R ;
Charbonnier, B ;
Barral, FG ;
Huet, Y ;
Simonneau, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (07) :409-415
[8]   EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER [J].
EPSTEIN, DH ;
DARCY, MD ;
HUNTER, DW ;
COLEMAN, CC ;
TADAVARTHY, SM ;
MURRAY, PD ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1989, 172 (01) :105-110
[9]   PERCUTANEOUS INFERIOR VENA-CAVAL FILTERS - FOLLOW-UP OF 7 DESIGNS IN 320 PATIENTS [J].
FERRIS, EJ ;
MCCOWAN, TC ;
CARVER, DK ;
MCFARLAND, DR .
RADIOLOGY, 1993, 188 (03) :851-856
[10]   INFERIOR VENA-CAVAL FILTERS - ANALYSIS OF 5 CURRENTLY AVAILABLE DEVICES [J].
GRASSI, CJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (04) :813-821