Stretchable, Multiplexed pH Sensors With Demonstrations on Rabbit and Human Hearts Undergoing Ischemia

被引:116
作者
Chung, Hyun-Joong [1 ,2 ]
Sulkin, Matthew S. [3 ]
Kim, Jong-Seon [4 ]
Goudeseune, Camille [5 ]
Chao, Hsin-Yun [2 ]
Song, Joseph W. [2 ]
Yang, Sang Yoon [2 ]
Hsu, Yung-Yu [6 ]
Ghaffari, Roozbeh [6 ]
Efimov, Igor R. [3 ]
Rogers, John A. [7 ,8 ]
机构
[1] Univ Alberta, Dept Chem & Mat Engn, Edmonton, AB T6G 2V4, Canada
[2] Univ Illinois, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[3] Washington Univ, Dept Biomed Engn, St Louis, MO 63130 USA
[4] Korea Adv Inst Sci & Technol, Dept Chem & Biomol Engn Program BK21, Taejon 305701, South Korea
[5] Univ Illinois, Illinois Simulator Lab, Beckman Inst, Urbana, IL 61801 USA
[6] MC10 Inc, Cambridge, MA 02140 USA
[7] Univ Illinois, Dept Mat Sci & Engn Chem, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[8] Univ Illinois, Frederick Seitz Mat Res Lab, Urbana, IL 61801 USA
关键词
heart ischemia; microfabrication; pH sensor; spatiotemporal mapping; stretchable electronics; NEAR-INFRARED SPECTROSCOPY; HYDROUS IRIDIUM OXIDE; OF-THE-ART; IN-VIVO; INTRACELLULAR PH; METAL-OXIDE; ELECTRONICS; STATE; FABRICATION; CIRCUITS;
D O I
10.1002/adhm.201300124
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stable pH is an established biomarker of health, relevant to all tissues of the body, including the heart. Clinical monitoring of pH in a practical manner, with high spatiotemporal resolution, is particularly difficult in organs such as the heart due to its soft mechanics, curvilinear geometry, heterogeneous surfaces, and continuous, complex rhythmic motion. The results presented here illustrate that advanced strategies in materials assembly and electrochemical growth can yield interconnected arrays of miniaturized IrOx pH sensors encapsulated in thin, low-modulus elastomers to yield conformal monitoring systems capable of noninvasive measurements on the surface of the beating heart. A thirty channel custom data acquisition system enables spatiotemporal pH mapping with a single potentiostat. In vitro testing reveals super-Nernstian sensitivity with excellent uniformity (69.9 +/- 2.2 mV/pH), linear response to temperature (-1.6 mV degrees C-1), and minimal influence of extracellular ions (<3.5 mV). Device examples include sensor arrays on balloon catheters and on skin-like stretchable membranes. Real-time measurement of pH on the surfaces of explanted rabbit hearts and a donated human heart during protocols of ischemia-reperfusion illustrate some of the capabilities. Envisioned applications range from devices for biological research, to surgical tools and long-term implants.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 47 条
[11]  
Gettin G., 2007, WOUNDS, V3, P52
[12]   METAL-METAL OXIDE AND METAL-OXIDE ELECTRODES AS PH SENSORS [J].
GLAB, S ;
HULANICKI, A ;
EDWALL, G ;
INGMAN, F .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1989, 21 (01) :29-47
[13]   Design of metal interconnects for stretchable electronic circuits [J].
Gonzalez, Mario ;
Axisa, Fabrice ;
BuIcke, Mathieu Vanden ;
Brosteaux, Dominique ;
Vandevelde, Bart ;
Vanfleteren, Jan .
MICROELECTRONICS RELIABILITY, 2008, 48 (06) :825-832
[14]   In vitro and in vivo measurements of fiber optic and electrochemical sensors to monitor brain tissue pH [J].
Grant, SA ;
Bettencourt, K ;
Krulevitch, P ;
Hamilton, J ;
Glass, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (02) :174-179
[15]   High-conductivity elastomeric electronics [J].
Gray, DS ;
Tien, J ;
Chen, CS .
ADVANCED MATERIALS, 2004, 16 (05) :393-+
[16]   NA+/H+ EXCHANGE AND GROWTH FACTOR-INDUCED CYTOSOLIC PH CHANGES - ROLE IN CELLULAR PROLIFERATION [J].
GRINSTEIN, S ;
ROTIN, D ;
MASON, MJ .
BIOCHIMICA ET BIOPHYSICA ACTA, 1989, 988 (01) :73-97
[17]   Functional and metabolic effects of extracellular magnesium in normoxic and ischemic myocardium [J].
Headrick, JP ;
McKirdy, JC ;
Willis, RJ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 275 (03) :H917-H929
[18]   A flexible pH sensor based on the iridium oxide sensing film [J].
Huang, Wen-Ding ;
Cao, Hung ;
Deb, Sanchali ;
Chiao, Mu ;
Chiao, J. C. .
SENSORS AND ACTUATORS A-PHYSICAL, 2011, 169 (01) :1-11
[19]   Tissue pH determination for the detection of metabolically active, inflamed vulnerable plaques using near-infrared spectroscopy: An in-vitro feasibility study [J].
Khan, T ;
Soller, B ;
Naghavi, M ;
Casscells, W .
CARDIOLOGY, 2005, 103 (01) :10-16
[20]   Electronic sensor and actuator webs for large-area complex geometry cardiac mapping and therapy [J].
Kim, Dae-Hyeong ;
Ghaffari, Roozbeh ;
Lu, Nanshu ;
Wang, Shuodao ;
Lee, Stephen P. ;
Keum, Hohyun ;
D'Angelo, Robert ;
Klinker, Lauren ;
Su, Yewang ;
Lu, Chaofeng ;
Kim, Yun-Soung ;
Ameen, Abid ;
Li, Yuhang ;
Zhang, Yihui ;
de Graff, Bassel ;
Hsu, Yung-Yu ;
Liu, ZhuangJian ;
Ruskin, Jeremy ;
Xu, Lizhi ;
Lu, Chi ;
Omenetto, Fiorenzo G. ;
Huang, Yonggang ;
Mansour, Moussa ;
Slepian, Marvin J. ;
Rogers, John A. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (49) :19910-19915