Application of a contactless conductometric detector for the simultaneous determination of small anions and cations by capillary electrophoresis with dual-opposite end injection

被引:102
作者
Kubán, P
Karlberg, B [1 ]
Kubán, P
Kubán, V
机构
[1] Stockholm Univ, Dept Analyt Chem, SE-10691 Stockholm, Sweden
[2] Mendel Univ Agr Brno, Dept Chem & Biochem, CZ-61300 Brno, Czech Republic
关键词
contactless conductivity detection; conductivity detection; detection; electrophoresis; inorganic anions; inorganic cations;
D O I
10.1016/S0021-9673(02)00656-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A contactless conductometric detection (CCD) system for capillary electrophoresis (CE) with a flexible detection cell was applied for the simultaneous determination of small anions and/or cations in rain, surface and drainage water samples. The applied frequency, the amplitude of the input signal. the electrolyte conductivity and electrode distance were found to be the most significant factors affecting the detection sensitivity. 2-(N-Morpholino)ethanesulfonic acid/histidine-based (MES/His) electrolytes were used for direct conductivity detection of anions and cations, while ammonium acetate was selected for indirect conductivity determination of alkylammonium salts. For the simultaneous separation procedure, involving dual-opposite end injection, an electrolyte consisting of 20 mM MES/His, 1.5 mM 18-crown-6 and 20 muM cetyltrimethylammonium bromide provided baseline separation of 13 anions and cations in less than 6 rain. The detection limits achieved were 7-30 mug/l for direct conductometric detection of various common inorganic cations and anions, excluding F- (62 mug/l) and H2PO(4) over bar (250 mug/l), and 35-178 mug/l for indirect conductometric detection of alkyl ammonium cations. The developed electrophoretic method with conductometric detection was compared to ion chromatography. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:227 / 241
页数:15
相关论文
共 61 条
  • [1] [Anonymous], J CHROMATOGR A
  • [2] DETERMINATION OF CATIONS AND ANIONS BY CAPILLARY ELECTROPHORESIS COMBINED WITH SUPPRESSED CONDUCTIVITY DETECTION
    AVDALOVIC, N
    POHL, CA
    ROCKLIN, RD
    STILLIAN, JR
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (10) : 1470 - 1475
  • [3] SIMULTANEOUS DETERMINATION OF INORGANIC CATIONS AND ANIONS IN CAPILLARY ZONE ELECTROPHORESIS (CZE) WITH INDIRECT FLUORESCENCE DETECTION
    BACHMANN, K
    HAUMANN, I
    GROH, T
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (12): : 901 - 902
  • [4] CAPILLARY ELECTROPHORESIS OF ORGANIC AND INORGANIC CATIONS WITH INDIRECT UV DETECTION
    BECK, W
    ENGELHARDT, H
    [J]. CHROMATOGRAPHIA, 1992, 33 (7-8) : 313 - 316
  • [5] SEPARATION OF NON UV-ABSORBING CATIONS BY CAPILLARY ELECTROPHORESIS
    BECK, W
    ENGELHARDT, H
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9): : 618 - 621
  • [6] OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS
    BURGI, DS
    CHIEN, RL
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (18) : 2042 - 2047
  • [7] ELECTROOSMOTIC PROPERTIES AND PEAK BROADENING IN FIELD-AMPLIFIED CAPILLARY ELECTROPHORESIS
    CHIEN, RL
    HELMER, JC
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (14) : 1354 - 1361
  • [8] Dual photometric-contactless conductometric detector for capillary electrophoresis
    Chvojka, T
    Jelínek, I
    Opekar, F
    Stulík, K
    [J]. ANALYTICA CHIMICA ACTA, 2001, 433 (01) : 13 - 21
  • [9] da Silva JAF, 2002, J CHROMATOGR A, V942, P249
  • [10] da Silva JAF, 1998, ANAL CHEM, V70, P4339