ICP-MS multi-element analysis of wine samples - a comparative study of the methodologies used in two laboratories

被引:49
作者
Almeida, CMR
Vasconcelos, MTSD
Barbaste, M
Medina, B
机构
[1] Univ Porto, LAQUIPAI, Dept Quim, Fac Ciencias, P-4169007 Oporto, Portugal
[2] DGCCRF, F-33405 Talence, France
关键词
wine; ICP-MS; multi-element; intercomparison;
D O I
10.1007/s00216-002-1467-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A comparison of the performance of the methodologies used in two distinct laboratories (Lab A and Lab B) for multi-element analysis in different wines was carried out. ICP-MS apparatus (quadrupole mass analyzers) of different brands as well as different wine pre-treatments were used. At Lab A, a pre-treatment by UV-irradiation was performed. At Lab B, a micro-concentric nebulizer was used for direct analysis of the wine. Twenty-six elements (Li, V, Co, Ni, Cu, Zn, Ga, As, Rb, Sr, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tin, Yb, Lu, and Pb) were measured in common at the two labs in three different wine samples (red and white Bordeaux table wines and Port wine) and the results were compared. The two methodologies provided similar LODs and similar precisions, with RSDs of 0.5-5%, for most of the elements. The recovery percentages were 85-120% at Lab A for the three wines, and 78-119% at Lab B for the Bordeaux wines, validating the accuracy of the methods used. Comparable results were obtained at both labs for ten elements (Li, V, Co, Ni, Cu, Zn, Rb, Sr, Ba, and Pb) in the three selected wines; the differences were lower than 10% in most cases. For REEs, the differences observed were slightly higher, but still in the acceptable range due to the sub-ppb levels involved. The results obtained for As and Ga were not comparable, due to methodological influence. A comparison through linear least-squares adjustment indicated that the results obtained by the two labs were linearly correlated (correlation coefficient =0.997) but statistically different as the slope was slightly, but significantly different from one, for a confidence level of 95% (the intercept was statistically identical to zero in any case). In the future, strictly more identical results can be achieved by using a reference wine sample.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 16 条
[1]   Advantages and limitations of the semi-quantitative operation mode of an inductively coupled plasma-mass spectrometer for multi-element analysis of wines [J].
Almeida, CM ;
Teresa, M ;
Vasconcelos, SD .
ANALYTICA CHIMICA ACTA, 2002, 463 (02) :165-175
[2]   ICP-MS determination of strontium isotope ratio in wine in order to be used as a fingerprint of its regional origin [J].
Almeida, CM ;
Vasconcelos, MTSD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) :607-611
[3]   UV-irradiation and MW-digestion pre-treatment of Port wine suitable for the determination of lead isotope ratios by inductively coupled plasma mass spectrometry [J].
Almeida, CMR ;
Vasconcelos, MTSD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1815-1821
[4]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[5]   Evaluation of the accuracy of the determination of lead isotope ratios in wine by ICP MS using quadrupole, multicollector magnetic sector and time-of-flight analyzers [J].
Barbaste, M ;
Halicz, L ;
Galy, A ;
Medina, B ;
Emteborg, H ;
Adams, FC ;
Lobinski, R .
TALANTA, 2001, 54 (02) :307-317
[6]  
Barbaste M., 2001, THESIS U PAU PAYS AD
[7]  
Baxter MJ, 1997, FOOD CHEM, V60, P443, DOI 10.1016/S0308-8146(96)00365-2
[8]   Development of a procedure for the multi-element determination of trace elements in wine by ICP-MS [J].
Castiñeira, MM ;
Brandt, R ;
von Bohlen, A ;
Jakubowski, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :553-558
[9]  
Greenough J. D., 1997, Australian Journal of Grape and Wine Research, V3, P75, DOI 10.1111/j.1755-0238.1997.tb00118.x
[10]  
Miller J. C., 1984, STAT ANAL CHEM