Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation

被引:49
作者
Waehnert, Dirk [1 ]
Schroeder, Richard [1 ]
Schulze, Martin [1 ]
Westerhoff, Peter [2 ]
Raschke, Michael [1 ]
Stange, Richard [1 ]
机构
[1] Univ Hosp Munster, Munster, Germany
[2] Univ Hosp Munster, Inst Expt, Munster, Germany
关键词
Periprosthetic; Vancouver B1 fracture; Cadaver; Biomechanics; Fixation; TOTAL HIP-ARTHROPLASTY; LOCKING ATTACHMENT PLATE; FEMORAL-SHAFT FRACTURES; PRINCIPLES; IMPLANT; RISK; TIP;
D O I
10.1007/s00264-013-2113-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Fractures of the femur associated with total hip arthroplasty are a significant concern in orthopaedic and trauma surgery. However, little is known about the different biomechanical properties of internal fixation systems in combination with periprosthetic fractures. In this study two new internal fixation systems for periprosthetic fractures are investigated using a cadaver fracture model simulating a Vancouver B1 periprosthetic femur fracture. Nine pairs of fresh-frozen cadaver femurs were scanned by dual X-ray absorptiometry. Cementless total hip prostheses were implanted and a periprosthetic femur fracture was simulated. Fractures were randomly fixed either with the fixed angle locking attachment plate (LAPA (R), Depuy SynthesA (R), Solothurn, Switzerland) or the variable angle non-contact bridging plate (NCBA (R), Zimmer GmbH, Winterthur, Switzerland). Each construct was cyclically loaded to failure in axial compression. Axial stiffness and cycles to failure were significantly higher in the NCB group. Both systems were able to be fixed well around the femoral stem. The two different internal fixation systems for periprosthetic fractures differed significantly in our setup. The non-contact bridging plate system revealed significantly higher failure load and may be the preferred option where high stability and load capacity is needed right after operation.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 22 条
[1]
Locking compression plate fixation of Vancouver type-b1 periprosthetic femoral fractures [J].
Buttaro, M. A. ;
Farfalli, G. ;
Nunez, M. Paredes ;
Comba, F. ;
Piccaluga, F. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :1964-1969
[2]
An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component [J].
Corten, K. ;
Vanrykel, F. ;
Bellemans, J. ;
Frederix, P. Reynders ;
Simon, J. -P. ;
Broos, P. L. O. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (11) :1424-1430
[3]
A Biomechanical Comparison of Periprosthetic Femoral Fracture Fixation in Normal and Osteoporotic Cadaveric Bone [J].
Demos, Harry A. ;
Briones, Marcus S. ;
White, Peter H. ;
Hogan, Kathleen A. ;
Barfield, William R. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (05) :783-788
[4]
Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :523-528
[5]
NCB-plating in the treatment of geriatric and periprosthetic femoral fractures [J].
El-Zayat, B. F. ;
Ruchholtz, S. ;
Efe, T. ;
Fuchs-Winkelmann, S. ;
Krueger, A. ;
Kreslo, D. ;
Zettl, R. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (07) :765-772
[6]
Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant [J].
Erhardt, J. B. ;
Grob, K. ;
Roderer, G. ;
Hoffmann, A. ;
Forster, T. N. ;
Kuster, M. S. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) :409-416
[7]
Garbuz DS, 1998, AAOS INSTR COURS LEC, V47, P237
[8]
Total hip arthroplasty with use of the cementless Zweymuller alloclassic system - A ten to thirteen-year follow-up study [J].
Garcia-Cimbrelo, E ;
Cruz-Pardos, A ;
Madero, R ;
Ortega-Andreu, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (02) :296-303
[9]
Principles of internal fixation and selection of implants for periprosthetic femoral fractures [J].
Giannoudis, Peter V. ;
Kanakaris, Nikolaos K. ;
Tsiridis, Eleftherios .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (06) :669-687
[10]
Minimally invasive periprosthetic plate osteosynthesis using the locking attachment plate [J].
Kammerlander, C. ;
Kates, S. L. ;
Wagner, M. ;
Roth, T. ;
Blauth, M. .
OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2013, 25 (04) :398-+