Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT

被引:52
作者
Borhani, Amir A. [1 ]
Kulzer, Matthew [2 ]
Iranpour, Negaur [2 ]
Ghodadra, Anish [2 ]
Sparrow, Mark [2 ]
Furlan, Alessandro [1 ]
Tublin, Mitchell E. [1 ]
机构
[1] Univ Pittsburgh, Sch Med, UPMC Presbyterian, Div Abdominal Imaging, Radiol Suite 200,East Wing,200 Lothrop St, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Med Ctr, UPMC Presbyterian, Dept Radiol, 200 Lothrop St, Pittsburgh, PA 15213 USA
关键词
Spectral CT; Dual-energy CT; Virtual unenhanced; Rapid kVp-switching CT; DUAL-ENERGY-CT; IMAGES; ACCURACY;
D O I
10.1007/s00261-016-0991-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objective: To assess the agreement between the true non-contrast (TNC) attenuation values of intra-abdominal structures and attenuation values obtained on virtual-unenhanced (VUE) images based on rapid kVp-switching dual-energy CT. The effects of contrast phase and patient characteristics (e.g., BMI, hematocrit, hemoglobin content) on VUE values were also investigated. Methods: Ninety four patients who underwent triphasic abdominal CT (liver mass protocol, n = 47; pancreas mass protocol, n = 47) between August 2014 and May 2015 were retrospectively reviewed. Unenhanced series was performed using conventional single-energy mode at 120 kVp. Late arterial and venous phase post-contrast series were obtained utilizing rapid kVp-switching dual-energy CT technique. VUE images were processed off of arterial (VUE-art) and venous (VUE-ven) phase series. Attenuation values of liver, pancreas, kidneys, adrenal glands, muscle, subcutaneous fat, aorta, IVC, and main portal vein were recorded on TNC and VUE sets of images. Attenuation values were compared using univariate linear regression and Student two-tailed paired t test. Results: There was excellent correlation between TNC, VUE-art, and VUE-ven attenuation values across all organs (p < 0.0001). Paired Student t test, however, showed significant difference between TNC and VUE-art attenuation of kidneys, right adrenal gland, paraspinal muscle, and aorta. There was also significant difference between TNC and VUE-ven attenuation of left kidney. Percentage of cases which had > 10 HU difference between VUE and TNC for an individual was calculated which ranged between 13% (right kidney) and 42% (right adrenal gland). Conclusion: Although the correlation between VUE and TNC attenuation values was excellent and mean difference between TNC and VUE attenuation values was negligible (ranging between -5.94 HU for paraspinal muscles to 6.2 HU in aorta), intra-patient analysis showed a considerable number of cases which had > 10 HU difference between VUE and TNC. VUE-ven generally offered a better approximation of TNC values. Further optimization of post-processing algorithms might be necessary before complete replacement of TNC with VUE images.
引用
收藏
页码:710 / 717
页数:8
相关论文
共 15 条
[1]
Incidental adrenal lesions detected on enhanced abdominal dual-energy CT: Can the diagnostic workup be shortened by the implementation of virtual unenhanced images? [J].
Botsikas, Diomidis ;
Triponez, Frederic ;
Boudabbous, Sana ;
Hansen, Catrina ;
Becker, Christoph D. ;
Montet, Xavier .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) :1746-1751
[2]
Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction [J].
De Cecco, Carlo N. ;
Muscogiuri, Giuseppe ;
Schoepf, U. Joseph ;
Caruso, Damiano ;
Wichmann, Julian L. ;
Cannao, Paola M. ;
Canstein, Christian ;
Fuller, Stephen R. ;
Snider, Lauren ;
Varga-Szemes, Akos ;
Hardie, Andrew D. .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (07) :1257-1264
[3]
Adrenal Incidentaloma Triage With Single-Source (Fast-Kilovoltage Switch) Dual-Energy CT [J].
Glazer, Daniel I. ;
Maturen, Katherine E. ;
Kaza, Ravi K. ;
Francis, Isaac R. ;
Keshavarzi, Nahid R. ;
Parker, Robert A. ;
Platt, Joel F. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) :329-335
[4]
Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440
[5]
Characterization of Adrenal Nodules With Dual-Energy CT: Can Virtual Unenhanced Attenuation Values Replace True Unenhanced Attenuation Values? [J].
Ho, Lisa M. ;
Marin, Daniele ;
Neville, Amy M. ;
Barnhart, Huiman X. ;
Gupta, Rajan T. ;
Paulson, Erik K. ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (04) :840-845
[6]
Tin-filter Enhanced Dual-Energy-CT: Image Quality and Accuracy of CT Numbers in Virtual Noncontrast Imaging [J].
Kaufmann, Sascha ;
Sauter, Alexander ;
Spira, Daniel ;
Gatidis, Sergios ;
Ketelsen, Dominik ;
Heuschmid, Martin ;
Claussen, Claus D. ;
Thomas, Christoph .
ACADEMIC RADIOLOGY, 2013, 20 (05) :596-603
[7]
Comparison of Virtual Unenhanced Images Derived From Dual-Energy CT With True Unenhanced Images in Evaluation of Gallstone Disease [J].
Lee, Han A. ;
Lee, Young Hwan ;
Yoon, Kwon-Ha ;
Bang, Dong-Ho ;
Park, Dong Eun .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (01) :74-80
[8]
Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates [J].
Li, Yongrui ;
Li, Ye ;
Jackson, Alan ;
Li, Xiaodong ;
Huang, Ning ;
Guo, Chunjie ;
Zhang, Huimao .
ABDOMINAL RADIOLOGY, 2017, 42 (01) :312-321
[9]
A Flexible Method for Multi-Material Decomposition of Dual-Energy CT Images [J].
Mendonca, Paulo R. S. ;
Lamb, Peter ;
Sahani, Dushyant V. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) :99-116
[10]
Effect of Organ Enhancement and Habitus on Estimation of Unenhanced Attenuation at Contrast-Enhanced Dual-Energy MDCT: Concepts for Individualized and Organ-Specific Spectral Iodine Subtraction Strategies [J].
Miller, Chad M. ;
Gupta, Rajan T. ;
Paulson, Erik K. ;
Neville, Amy M. ;
Bashir, Mustafa R. ;
Merkle, Elmar M. ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) :W558-W564