Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echo-planar MR imaging sequences: Prospective study in 66 patients

被引:458
作者
Taouli, B [1 ]
Vilgrain, V
Dumont, E
Daire, JL
Fan, B
Menu, Y
机构
[1] Hop Beaujon, Dept Radiol, Clichy, France
[2] Fac Med Paris 7, Lab Imagerie Med Paris Nord, Clichy, France
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
liver; diseases; focal nodular hyperplasia; liver neoplasms; MR; magnetic resonance (MR); diffusion study; echo planar;
D O I
10.1148/radiol.2261011904
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To (a) evaluate liver diffusion isotropy, (b) compare two diffusion-weighted magnetic resonance (MR) imaging sequences for the characterization of focal hepatic lesions by using two or four b values, and (c) determine an apparent diffusion coefficient (ADC) threshold value to differentiate benign from malignant lesions. MATERIALS AND METHODS: Sixty-six patients were examined with two single-shot echo-planar diffusion-weighted MR sequences. In the first sequence, liver diffusion isotropy was evaluated by using diffusion gradients in three directions with two b values. In the second sequence a unidirectional diffusion gradient was used, with four b values. ADCs were measured in 43 patients with 52 focal hepatic lesions more than I cm in diameter and in 23 patients with 14 normal and nine cirrhotic livers and were compared by using nonparametric tests. RESULTS: Diffusion in the liver parenchyma was isotropic. ADCs of focal hepatic lesions were significantly different between sequences (P < .01). The mean (+/-SD) ADCs in the first sequence were 0.94 X 10(-3) mm(2)/sec +/- 0.60 for metastases, 1.33 X 10(-3) mm(2)/sec +/- 0.13 for HCCs, 1.75 X 10(-3) mm(2)/sec +/- 0.46 for benign hepatocellular lesions, 2.95 X 10(-3) mm(2)/sec +/- 0.67 for hemangiomas, and 3.63 X 10(-3) mm(2)/sec +/- 0.56 for cysts. There was a significant difference between benign (2.45 X 10(-3) mm(2)/sec +/- 0.96, isotropic value) and malignant (1.08 X 10(-3) mm(2)/sec +/- 0.50) lesions (P < .01 for both sequences). CONCLUSION: Diffusion-weighted MR imaging can help differentiate benign from malignant hepatic lesions. The use of two b values in one direction could be sufficient for the design of MR sequences in the liver. (C) RSNA, 2002.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 34 条
  • [1] Amano Y, 1998, ACTA RADIOL, V39, P440
  • [2] HEPATIC ADENOMA - MR FINDINGS IN 51 PATHOLOGICALLY PROVED LESIONS
    ARRIVE, L
    FLEJOU, JF
    VILGRAIN, V
    BELGHITI, J
    NAJMARK, D
    ZINS, M
    MENU, Y
    TUBIANA, JM
    NAHUM, H
    [J]. RADIOLOGY, 1994, 193 (02) : 507 - 512
  • [3] MRI of carcinoid tumors: Spectrum of appearances in the gastrointestinal tract and liver
    Bader, TR
    Semelka, RC
    Chiu, VCY
    Armao, DM
    Woosley, JT
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) : 261 - 269
  • [4] Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system
    Bammer, P
    Stollberger, R
    Augustin, M
    Simbrunner, J
    Offenbacher, H
    Kooijman, H
    Ropele, S
    Kapeller, P
    Wach, P
    Ebner, F
    Fazekas, F
    [J]. RADIOLOGY, 1999, 211 (03) : 799 - 806
  • [5] Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE)
    Bammer, R
    Keeling, SL
    Augustin, M
    Pruessmann, KP
    Wolf, R
    Stollberger, R
    Hartung, HP
    Fazekas, F
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 548 - 554
  • [6] Differentiation between multiple liver hemangiomas and liver metastases of gastrinomas: Value of enhanced MRI
    Berger, JF
    Laissy, JP
    Limot, O
    HenryFeugeas, MC
    Cadiot, G
    Mignon, M
    SchoumanClaeys, E
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (03) : 349 - 355
  • [7] Quantitative diffusion coefficient maps using fast spin-echo MRI
    Brockstedt, S
    Thomsen, C
    Wirestam, R
    Holtås, S
    Ståhlberg, F
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (08) : 877 - 886
  • [8] ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    FELMLEE, JP
    GRIMM, RC
    [J]. RADIOLOGY, 1993, 189 (01) : 259 - 264
  • [9] Diffusion-weighted MR imaging of the liver: distinguishing hepatic abscess from cystic or necrotic tumor
    Chan, JHM
    Tsui, EYK
    Luk, SH
    Fung, ASL
    Yuen, MK
    Szeto, ML
    Cheung, YK
    Wong, KPC
    [J]. ABDOMINAL IMAGING, 2001, 26 (02): : 161 - 165
  • [10] ECHO-PLANAR MR-IMAGING
    EDELMAN, RR
    WIELOPOLSKI, P
    SCHMITT, F
    [J]. RADIOLOGY, 1994, 192 (03) : 600 - 612