Quantitative imaging and correction for cascade gamma radiation of 76Br with 2D and 3D PET

被引:55
作者
Lubberink, M [1 ]
Schneider, H
Bergström, M
Lundqvist, H
机构
[1] Uppsala Univ, Rudbeck Lab, Sect Biomed Radiat Sci, S-75185 Uppsala, Sweden
[2] Uppsala Univ, PET Ctr, Univ Hosp, Uppsala Res Imaging Solut AB, S-75185 Uppsala, Sweden
关键词
D O I
10.1088/0031-9155/47/19/306
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several positron emitting nuclides with applications in PET, such as Br-76, I-124, In-110m and Y-86, also emit gamma radiation in their decays. Measured coincidences between annihilation photons and this cascade gamma radiation are essentially true coincidences and the standard PET corrections do not account for them. We investigated the performance of Br-76 in 2D and 3D PET, the effect of the gamma radiation emitted by Br-76 on quantitative accuracy and the distribution of cascade gamma radiation coincidences in 2D and 3D PET sinograms. A correction method for cascade gamma radiation coincidences was implemented and evaluated. Count rate linearity was affected by the gamma radiation from the Br-76 decay. Spatial resolution and sphere recovery were slightly worse for Br-76 compared to F-18. Correction for cascade gamma radiation coincidences by subtraction of a linear projection tail fit improved total correction accuracy to similar values as for positron-only emitters such as F-18, and improved image contrast significantly.
引用
收藏
页码:3519 / 3534
页数:16
相关论文
共 26 条
[1]   Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard [J].
Adam, LE ;
Zaers, J ;
Ostertag, H ;
Trojan, H ;
Bellemann, ME ;
Brix, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1172-1179
[2]  
Beattie BJ, 2001, J NUCL MED, V42, p201P
[3]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[4]   Pharmacokinetics and red cell utilization of iron(III) hydroxide-sucrose complex in anaemic patients:: a study using positron emission tomography [J].
Beshara, S ;
Lundqvist, H ;
Sundin, J ;
Lubberink, M ;
Tolmachev, V ;
Valind, S ;
Antoni, G ;
Långström, B ;
Danielson, BG .
BRITISH JOURNAL OF HAEMATOLOGY, 1999, 104 (02) :296-302
[5]  
Brix G, 1997, J NUCL MED, V38, P1614
[6]  
CHU S. Y. F., 1999, WWW TABLE RADIOACTIV
[7]  
FLOWER MA, 1994, EUR J NUCL MED, V21, P531
[8]   Recovery correction for quantitation in emission tomography: a feasibility study [J].
Geworski, L ;
Knoop, BO ;
de Cabrejas, ML ;
Knapp, WH ;
Munz, DL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (02) :161-169
[9]   An investigation of the physical characteristics of Ga-66 as an isotope for PET imaging and quantification [J].
Graham, MC ;
Pentlow, KS ;
Mawlawi, O ;
Finn, RD ;
Daghighian, F ;
Larson, SM .
MEDICAL PHYSICS, 1997, 24 (02) :317-326
[10]   PET quantitation and imaging of the non-pure positronemitting iodine isotope 124I [J].
Herzog, H ;
Tellmann, L ;
Qaim, SM ;
Spellerberg, S ;
Schmid, A ;
Coenen, HH .
APPLIED RADIATION AND ISOTOPES, 2002, 56 (05) :673-679