3D Contrast-enhanced MR angiography

被引:98
作者
Zhang, HongLei
Maki, Jeffrey H.
Prince, Martin R.
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY USA
[2] Cornell Univ, Coll Phys & Surg, Dept Radiol, New York, NY USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
MR angiography; contrast enhanced; gadolinium; cardiovascular disease; thigh compression; atherosclerosis;
D O I
10.1002/jmri.20767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Safe, fast, accurate contrast arteriography can be obtained utilizing gadolinium (Gd) and 3D MR, data acquisition for diagnosing vascular diseases. Optimizing contrasts enhanced MRA (CE MRA), however, requires understanding the complex interplay between Gd injection timing, the Fourier mapping of 3D MR data acquisition and a multi- tude of parameters determining resolution, anatomic cov- erage, and sensitivity to motion artifacts. It is critical to time the bolus peak to coincide with central k-space data acquisition, which dominates, image contrast. Oversampling the center of k-space, allows reconstruction of multiple 3D acquisitions, in rapid succession to time-resolve the passage of the contrast bolus. Parallel imaging increases resolution, shortens scan time and compresses, the center of k-space into a shorter period of time, thereby minimizing motion and timing artifacts. Absence of ionizing radiation allows MRA to be repeated and combined, with"additional sequences to more fully characterize anatomy,e flow, and physiology. Utilizing stepping table technology and thigh compression. whole body MRA is, possible with a single contrast injection. As MR technology continue's to advance, CE MRA becomes better and simpler to perform, increasing its efficacy in the diagnosis and management of vascular diseases.
引用
收藏
页码:13 / 25
页数:13
相关论文
共 122 条
[1]   Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model [J].
Bae, KT .
RADIOLOGY, 2003, 227 (03) :809-816
[2]   Contrast-enhanced 4D radial coronary artery imaging at 3.0 T within a single breath-hold [J].
Bi, XM ;
Park, J ;
Larson, AC ;
Zhang, Q ;
Simonetti, O ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :470-475
[3]   Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes [J].
Boos, M ;
Scheffler, K ;
Haselhorst, R ;
Reese, E ;
Fröhlich, J ;
Bongartz, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :568-576
[4]   Sensitivity encoding (SENSE) for contrast enhanced 3D MR angiography of the abdominal arteries [J].
Born, M ;
Willinek, WA ;
Gieseke, J ;
von Falkenhausen, M ;
Schild, H ;
Kuhl, CK .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (04) :559-565
[5]   High-resolution contrast-enhanced magnetic resonance angiography of the carotid arteries using fluoroscopic monitoring of contrast arrival: Diagnostic accuracy and interobserver variability [J].
Butz, B ;
Dorenbeck, U ;
Borisch, I ;
Zorger, N ;
Lenhart, M ;
Feuerbach, S ;
Link, J .
ACTA RADIOLOGICA, 2004, 45 (02) :164-170
[6]   Time-resolved three-dimensional pulmonary MR angiography and perfusion imaging with ultrashort repetition time [J].
Carr, JC ;
Laub, G ;
Zheng, J ;
Pereles, FS ;
Finn, JP .
ACADEMIC RADIOLOGY, 2002, 9 (12) :1407-1418
[7]   The effect of injection rate on time-resolved contrast-enhanced peripheral MRA [J].
Carroll, TJ ;
Korosec, FR ;
Swan, JS ;
Hany, TF ;
Grist, TM ;
Mistretta, CA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) :401-410
[8]   Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography [J].
Carroll, TJ ;
Korosec, FR ;
Petermann, GM ;
Grist, TM ;
Turski, PA .
RADIOLOGY, 2001, 220 (02) :525-532
[9]  
Chung Taylor, 2004, Top Magn Reson Imaging, V15, P187, DOI 10.1097/01.rmr.0000135285.76847.ab
[10]   Dynamic magnetic resonance imaging in the assessment of chronic medical nephropathies with impaired renal function [J].
Dalla-Palma, L ;
Panzetta, G ;
Pozzi-Mucelli, RS ;
Galli, G ;
Cova, M ;
Meduri, S .
EUROPEAN RADIOLOGY, 2000, 10 (02) :280-286