3D Contrast-enhanced MR angiography

被引:98
作者
Zhang, HongLei
Maki, Jeffrey H.
Prince, Martin R.
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY USA
[2] Cornell Univ, Coll Phys & Surg, Dept Radiol, New York, NY USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
MR angiography; contrast enhanced; gadolinium; cardiovascular disease; thigh compression; atherosclerosis;
D O I
10.1002/jmri.20767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Safe, fast, accurate contrast arteriography can be obtained utilizing gadolinium (Gd) and 3D MR, data acquisition for diagnosing vascular diseases. Optimizing contrasts enhanced MRA (CE MRA), however, requires understanding the complex interplay between Gd injection timing, the Fourier mapping of 3D MR data acquisition and a multi- tude of parameters determining resolution, anatomic cov- erage, and sensitivity to motion artifacts. It is critical to time the bolus peak to coincide with central k-space data acquisition, which dominates, image contrast. Oversampling the center of k-space, allows reconstruction of multiple 3D acquisitions, in rapid succession to time-resolve the passage of the contrast bolus. Parallel imaging increases resolution, shortens scan time and compresses, the center of k-space into a shorter period of time, thereby minimizing motion and timing artifacts. Absence of ionizing radiation allows MRA to be repeated and combined, with"additional sequences to more fully characterize anatomy,e flow, and physiology. Utilizing stepping table technology and thigh compression. whole body MRA is, possible with a single contrast injection. As MR technology continue's to advance, CE MRA becomes better and simpler to perform, increasing its efficacy in the diagnosis and management of vascular diseases.
引用
收藏
页码:13 / 25
页数:13
相关论文
共 122 条
[41]   Contrast-enhanced magnetic resonance angiography of the carotid arteries:: Influence of injection rates and volumes on arterial-venous transit time [J].
Herold, T ;
Paetzel, C ;
Völk, M ;
Bachthaler, M ;
Zorger, N ;
Feuerbach, S ;
Strotzer, M ;
Lenhart, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (02) :65-72
[42]   MR angiography of the abdominal aorta and peripheral vessels [J].
Ho, VB ;
Corse, WR .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2003, 41 (01) :115-+
[43]   Mr digital subtraction angiography with asymmetric echo acquisition and complex subtraction: Improved lumen and stenosis visualization [J].
Hoogeveen, RM ;
Bakker, CJG ;
Viergever, MA .
MAGNETIC RESONANCE IMAGING, 1999, 17 (02) :305-311
[44]   Combination of 2D sensitivity encoding and 2D partial Fourier techniques for improved acceleration in 3D contrast-enhanced MR angiography [J].
Hu, HCH ;
Madhuranthakam, AJ ;
Kruger, DG ;
Glockner, JF ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) :16-22
[45]   Contrast-enhanced MR angiography of the run-off vasculature: Intraindividual comparison of gadobenate dimeglumine with gadopentetate dimeglumine [J].
Knopp, MV ;
Giesel, FL ;
von Tengg-Kobligk, H ;
Radeleff, J ;
Requardt, M ;
Kirchin, MA ;
Hentrich, HR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (06) :694-702
[46]   Non-invasive assessment of renal artery stenosis: Current concepts and future directions in magnetic resonance angiography [J].
Knopp, MV ;
Floemer, F ;
Schoenberg, SO ;
von Tengg-Kobligk, H ;
Bock, M ;
van Kaick, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 :S111-S117
[47]   Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography [J].
Kopka, L ;
Vosshenrich, R ;
Rodenwaldt, J ;
Grabbe, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :345-348
[48]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[49]   Time-resolved contrast-enhanced magnetic resonance angiography of the lower extremity [J].
Krause, UJ ;
Pabst, T ;
Kenn, W ;
Wittenberg, G ;
Hahn, D .
ANGIOLOGY, 2004, 55 (02) :119-125
[50]   Gadolinium-enhanced three-dimensional magnetic resonance angiography of the thoracic aorta and arch vessels - A review [J].
Krinsky, G .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :587-605