Genetic typing and HIV-1 diagnosis by using 96 capillary array electrophoresis and ultraviolet absorption detection

被引:18
作者
Gong, XY
Yeung, ES [1 ]
机构
[1] Iowa State Univ, Ames Lab, USDOE, Ames, IA 50011 USA
[2] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 741卷 / 01期
基金
美国国家卫生研究院;
关键词
genetic typing;
D O I
10.1016/S0378-4347(00)00165-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Current high-throughput approaches to the analysis of PCR products are based primarily on electrophoretic separation and laser-excited fluorescence detection. We show that capillary array electrophoresis can be applied to HIV-1 diagnosis and D1S80 VNTR genetic typing based simply on UV absorption detection. The additive contribution of each base pair to the total absorption signal provides adequate detection sensitivity for analyzing most PCR products. Not only is the use of specialized and potentially toxic fluorescent labels eliminated, but also the complexity and cost of the instrumentation are greatly reduced. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 37 条
[1]   A capillary array gel electrophoresis system using multiple laser focusing for DNA sequencing [J].
Anazawa, T ;
Takahashi, S ;
Kambara, H .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2699-2704
[2]   ANALYSIS OF POLYMERASE CHAIN-REACTION PRODUCT BY CAPILLARY ELECTROPHORESIS AND ITS APPLICATION TO THE DETECTION OF SINGLE-BASE SUBSTITUTION IN GENES [J].
ARAKAWA, H ;
UETANAKA, K ;
MAEDA, M ;
TSUJI, A .
JOURNAL OF CHROMATOGRAPHY A, 1994, 664 (01) :89-98
[3]   RAPID TYPING OF VARIABLE NUMBER OF TANDEM REPEAT LOCUS IN THE HUMAN APOLIPOPROTEIN-B GENE FOR DNA DIAGNOSIS OF HEART-DISEASE BY POLYMERASE CHAIN-REACTION AND CAPILLARY ELECTROPHORESIS [J].
BABA, Y ;
TOMISAKI, R ;
SUMITA, C ;
MORIMOTO, I ;
SUGITA, S ;
TSUHAKO, M ;
MIKI, T ;
OGIHARA, T .
ELECTROPHORESIS, 1995, 16 (08) :1437-1440
[4]   THE USE OF COATED AND UNCOATED CAPILLARIES FOR THE ELECTROPHORETIC SEPARATION OF DNA IN DILUTE POLYMER-SOLUTIONS [J].
BARRON, AE ;
SUNADA, WM ;
BLANCH, HW .
ELECTROPHORESIS, 1995, 16 (01) :64-74
[5]   APPLICATION OF DUAL INTERNAL STANDARDS FOR PRECISE SIZING OF POLYMERASE CHAIN-REACTION PRODUCTS USING CAPILLARY ELECTROPHORESIS [J].
BUTLER, JM ;
MCCORD, BR ;
JUNG, JM ;
LEE, JA ;
BUDOWLE, B ;
ALLEN, RO .
ELECTROPHORESIS, 1995, 16 (06) :974-980
[6]   Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions [J].
Carrilho, E ;
RuizMartinez, MC ;
Berka, J ;
Smirnov, I ;
Goetzinger, W ;
Miller, AW ;
Brady, D ;
Karger, BL .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3305-3313
[7]   POLY(ETHYLENEOXIDE) FOR HIGH-RESOLUTION AND HIGH-SPEED SEPARATION OF DNA BY CAPILLARY ELECTROPHORESIS [J].
CHANG, HT ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 669 (01) :113-123
[8]  
CHENG J, 1995, J CAPILLARY ELECTROP, V2, P24
[9]  
FELMLEE TA, 1995, J CAPILLARY ELECTROP, V2, P125
[10]   HIGH-SPEED DNA-SEQUENCING BY USING MIXED POLY(ETHYLENE OXIDE) SOLUTIONS IN UNCOATED CAPILLARY COLUMNS [J].
FUNG, EN ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :1913-1919