Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model

被引:46
作者
Kawase, Yoshiaki
Suzuki, Yoriyasu
Ikeno, Fumiaki
Yoneyama, Ryuichi
Hoshino, Kozo
Ly, Hung Q.
Lau, George T.
Hayase, Motoya
Yeung, Alan C.
Hajjar, Roger J.
Jang, Ik-Kyung
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Cardiol Lab Integrat Physiol & Imaging, Boston, MA 02114 USA
[2] Stanford Med Ctr, Div Cardiovasc Med, Stanford, CA USA
关键词
optical coherence tomography; mechanical intravascular ultrasound; nonuniform rotational distortion;
D O I
10.1016/j.ultrasmedbio.2006.07.020
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Optical coherence tomography (OCT) is an optical analog of mechanical intravascular ultrasound (M-IVUS) with much higher spatial resolution. However, no data exist regarding the nonuniform rotational distortion (NURD) with OCT. The aim of the study was to investigate whether OCT generates less NURD relative to M-IVUS. A coronary artery phantom model was constructed with a rubber ring (3.68 mm in diameter), located at the distal end of the phantom. This model was also composed of eight equally spaced steel wires and an additional marker-wire. Two types of vascular phantoms were used, mild curve (90 degrees) and acute curve (near 180 degrees). Subsequent M-IVUS (n = 6) and OCT (n = 6) imaging was performed. Eight angles between eight wires, except the marker-wire, were measured from each image. These angles, measured with M-IVUS and OCT, were compared with those of high-resolution optical photography as a gold standard. The average in angle differences was significantly smaller in OCT compared with M-IVUS in the mild curve model (3.2 +/- 1.0 degrees vs, 6.9 +/- 2.11 degrees, p < 0.01). Compared with the latter model, the average in angle differences was exaggerated in the acute curve model with M-IVUS (9.1 +/- 0.9 degrees vs. 6.9 +/- 2.1 degrees p < 0.05) but not with OCT (3.5 +/- 0.8 degrees vs. 3.2 +/- 1.0 degrees, p = not significant). OCT generates significantly less NURD compared with M-IVUS, especially in tortuous situation. (E-mail: ijang@partners.org) (c) 2006 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 23 条
[1]   Evaluation of intracoronary stenting by intravascular optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Yabushita, H ;
Shishkov, M ;
Kauffman, CR ;
Gauthier, DD ;
MacNeill, BD ;
Houser, SL ;
Aretz, HT ;
Halpern, EF ;
Jang, IK .
HEART, 2003, 89 (03) :317-320
[2]   Optical coherence tomography as a tool for percutaneous coronary interventions [J].
Diaz-Sandoval, LJ ;
Bourna, BE ;
Tearney, GJ ;
Jang, IK .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (04) :492-496
[3]   Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents [J].
Finn, AV ;
Kolodgie, FD ;
Harnek, J ;
Guerrero, LJ ;
Acampado, E ;
Tefera, K ;
Skorija, K ;
Weber, DK ;
Gold, HK ;
Virmani, R .
CIRCULATION, 2005, 112 (02) :270-278
[4]   In vitro and in vivo comparison of three different intravascular ultrasound catheter designs [J].
Fort, S ;
Freeman, NA ;
Johnston, P ;
Cohen, EA ;
Foster, FS .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (03) :382-392
[5]   High resolution in vivo intra-arterial imaging with optical coherence tomography [J].
Fujimoto, JG ;
Boppart, SA ;
Tearney, GJ ;
Bouma, BE ;
Pitris, C ;
Brezinski, ME .
HEART, 1999, 82 (02) :128-133
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Physiological transport forces govern drug distribution for stent-based delivery [J].
Hwang, CW ;
Wu, D ;
Edelman, ER .
CIRCULATION, 2001, 104 (05) :600-605
[8]   In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography [J].
Jang, IK ;
Tearney, GJ ;
MacNeill, B ;
Takano, M ;
Moselewski, F ;
Iftima, N ;
Shishkov, M ;
Houser, S ;
Aretz, HT ;
Halpern, EF ;
Bouma, BE .
CIRCULATION, 2005, 111 (12) :1551-1555
[9]   Sirolimus-eluting stents vs paclitaxel-eluting stents in patients with coronary artery disease -: Meta-analysis of randomized trials [J].
Kastrati, A ;
Dibra, A ;
Eberle, S ;
Mehilli, J ;
de Lezo, JS ;
Goy, JJ ;
Ulm, K ;
Schömig, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (07) :819-825
[10]   In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter:: A comparison with intravascular ultrasound [J].
Kawase, Y ;
Hoshino, K ;
Yoneyama, R ;
McGregor, J ;
Hajjar, RJ ;
Jang, IK ;
Hayase, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (10) :1343-1349