Flow injection on-line preconcentration of palladium by ion-pair adsorption in a knotted reactor coupled with electrothermal atomic absorption spectrometry

被引:117
作者
Dimitrova, B
Benkhedda, K
Ivanova, E
Adams, F
机构
[1] Univ Antwerp, Dept Chem, Microtrace Anal Ctr, B-2610 Antwerp, Belgium
[2] Bulgarian Acad Sci, Inst Gen & Inorgan Chem, BU-1113 Sofia, Bulgaria
关键词
D O I
10.1039/b407546n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (FI) method for the preconcentration/separation of palladium, coupled with electrothermal atomic absorption spectrometry (ETAAS), is presented. The preconcentration was performed by on-line formation of an ion-pair between the positively charged potassium complex of 1,4,7,10,13,16-hexaoxacyclooctadecane ( K+ 18-crown-6) and the palladium thiocyanate anion (Pd(SCN)(4)(2-)) and its sorption on the inner walls of a PTFE knotted reactor (KR). The elution was achieved by methanol acidified with 1% (v/v) HNO3. An enhancement factor of 29 and a sampling frequency of 14 h(-1) were obtained for a preconcentration time of 90 s and a sampling flow rate of 4.4 ml min(-1). The detection limit (3sigma) is 16 ng l(-1) and precision (RSD) for 0.4 mug l(-1) Pd is 2.3%. The method was validated by recovery measurements on spiked blood and road dust samples.
引用
收藏
页码:1394 / 1396
页数:3
相关论文
共 13 条
[1]  
Benkhedda I, 1999, J ANAL ATOM SPECTROM, V14, P957
[2]   Simultaneous on-line preconcentration and determination of Pt, Rh and Pd in urine, serum and road dust by flow injection combined with inductively coupled plasma time-of-flight mass spectrometry [J].
Benkhedda, K ;
Dimitrova, B ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) :1019-1025
[3]   Ultratrace determination of cobalt in natural waters by electrothermal atomic absorption spectrometry using flow-injection on-line sorption preconcentration in a knotted reactor precoated with 1-phenyl-3-methyl-benzoylpyrazol-5-one [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :429-434
[4]   On the determination of platinum group elements in environmental materials by inductively coupled plasma mass spectrometry and microwave digestion [J].
Djingova, R ;
Heidenreich, H ;
Kovacheva, P ;
Markert, B .
ANALYTICA CHIMICA ACTA, 2003, 489 (02) :245-251
[5]   ICP-MS determination of Pt, Pd and Rh in airborne and road dust after tellurium coprecipitation [J].
Gómez, MB ;
Gómez, MM ;
Palacios, MA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) :80-83
[6]   Determination of copper, manganese and nickel in biological samples and sea-water by flow injection on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry [J].
Ivanova, E ;
Benkhedda, K ;
Adams, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (06) :527-531
[7]   Ion-exchange method for separation and concentration of platinum and palladium for analysis of environmental samples by inductively coupled plasma atomic emission spectrometry [J].
Kovacheva, P ;
Djingova, R .
ANALYTICA CHIMICA ACTA, 2002, 464 (01) :7-13
[8]   ETAAS determination of palladium in environmental samples with on-line preconcentration and matrix separation [J].
Limbeck, A ;
Rendl, J ;
Puxbaum, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (02) :161-165
[9]   Determination of platinum, rhodium and palladium in car exhaust fumes [J].
Moldovan, M ;
Gómez, MM ;
Palacios, MA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1163-1169
[10]   On-line preconcentration of palladium on alumina microcolumns and determination in urban waters by inductively coupled plasma mass spectrometry [J].
Moldovan, M ;
Gómez, MM ;
Palacios, MA .
ANALYTICA CHIMICA ACTA, 2003, 478 (02) :209-217