Depth scanning for a conformal ion beam treatment of deep seated tumours

被引:31
作者
Weber, U [1 ]
Becher, W [1 ]
Kraft, G [1 ]
机构
[1] Gesell Schwerionenforsch, Biophys, D-64291 Darmstadt, Germany
关键词
D O I
10.1088/0031-9155/45/12/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Only target-conformal treatment allows one to exploit the advantages of ion beams (the increased dose and high biological efficiency at the end of the particle range) to a maximum extent. Up to now, target-conformal treatments such as spot scanning or intensity-controlled raster scanning have used fast magnetic lateral deflection in one or two directions perpendicular to the beam axis and a slow range variation in the longitudinal axis by active or passive energy variation. The present paper describes a new method for conformal irradiation with a fast intensity-controlled longitudinal scan in the beam direction, called 'depth scanning'. Its advantages and disadvantages will be discussed. First experimental results from depth scanning will be presented.
引用
收藏
页码:3627 / 3641
页数:15
相关论文
共 19 条
[11]  
KRAFT G, 1998, Patent No. 199070989
[12]  
KRAFT G, 1998, Patent No. 0001149
[13]   Treatment planning for heavy-ion radiotherapy:: physical beam model and dose optimization [J].
Krämer, M ;
Jäkel, O ;
Haberer, T ;
Kraft, G ;
Schardt, D ;
Weber, U .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3299-3317
[14]   NMR RELAXATION ENHANCEMENT IN GELS POLYMERIZED AND CROSS-LINKED BY IONIZING-RADIATION - A NEW APPROACH TO 3D DOSIMETRY BY MRI [J].
MARYANSKI, MJ ;
GORE, JC ;
KENNAN, RP ;
SCHULZ, RJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (02) :253-258
[15]   Beam-optics study of the gantry beam delivery system for light-ion cancer therapy [J].
Pavlovic, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 399 (2-3) :439-454
[16]   THE 200-MEV PROTON THERAPY PROJECT AT THE PAUL-SCHERRER-INSTITUTE - CONCEPTUAL DESIGN AND PRACTICAL REALIZATION [J].
PEDRONI, E ;
BACHER, R ;
BLATTMANN, H ;
BOHRINGER, T ;
CORAY, A ;
LOMAX, A ;
LIN, SX ;
MUNKEL, G ;
SCHEIB, S ;
SCHNEIDER, U ;
TOUROVSKY, A .
MEDICAL PHYSICS, 1995, 22 (01) :37-53
[17]   Three-dimensional BANG™ gel dosimetry in conformal carbon ion radiotherapy [J].
Ramm, U ;
Weber, U ;
Bock, M ;
Krämer, M ;
Bankamp, A ;
Damrau, M ;
Thilmann, C ;
Bottcher, HD ;
Schad, LR ;
Kraft, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :N95-N102
[18]  
RAMM U, 1999, GSIREP991, P132
[19]  
SCHARDT D, 1992, GSI931, P336