Development of a tyrosinase biosensor based on gold nanoparticles-modified glassy carbon electrodes -: Application to the measurement of a bioelectrochemical polyphenols index in wines

被引:255
作者
Sanz, VC [1 ]
Mena, ML [1 ]
González-Cortés, A [1 ]
Yáñez-Sedeño, P [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
gold nanocrystal-modified glassy carbon electrodes; tyrosinase biosensors; phenolic compounds; wines;
D O I
10.1016/j.aca.2004.10.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation of a tyrosinase biosensor based on the immobilization of the enzyme onto a glassy carbon electrode modified with electrodeposited gold nanoparticles (Tyr-nAu-GCE) is reported. The enzyme immobilized by cross-linking with glutaraldehyde retains a high bioactivity on this electrode material. Under the optimized working variables (a An electrodeposition potential of -200 mV for 60 s. an enzyme loading of 457U, a detection potential of -0.10V and a 0.1 mol 1(-1) phosphate buffer solution of pH 7-4 as working medium) the biosensor exhibited a rapid response to the changes in the substrate concentration for all the phenolic compounds tested: phenol, catechol. caffeic acid, chlorogenic acid, gallic acid and protocatechualdehyde. AR.S.D. of 3.6% (n = 6) was obtained from the slope values of successive calibration plots for catechol with the same Tyr-nAu-GCE with no need to apply a cleaning procedure to the biosensor. The useful lifetime of one single biosensor was of at least 18 days, and a R.S.D. of 4.8% was obtained for the slope values of catechol calibradon plots obtained with five different biosensors. The kinetic constants and the analytical characteristics were calculated for all the phenolic compounds tested. The Tyr-nAu-GCE was applied for the estimation of the phenolic compounds content in red and white wines. A good correlation of the results (r = 0.990) was found when they were plotted versus those obtained by using the spectrophotometric method involving the Folin-Ciocalteau reagent. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 28 条
[1]   Biosensors for determination of total and natural antioxidant capacity of red and white wines: comparison with other spectrophotometric and fluorimetric methods [J].
Campanella, L ;
Bonanni, A ;
Finotti, E ;
Tomassetti, M .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (07) :641-651
[2]   Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors [J].
Campuzano, S ;
Serra, B ;
Pedrero, M ;
de Villena, FJM ;
Pingarrón, JM .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :187-197
[3]  
CARRALERO SV, IN PRESS ELECTROANAL
[4]   Disposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols [J].
Chang, SC ;
Rawson, K ;
McNeil, CJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1015-1023
[5]   Characterization of electrochemically deposited gold nanocrystals on glassy carbon electrodes [J].
Finot, MO ;
Braybrook, GD ;
McDermott, MT .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 466 (02) :234-241
[6]   Characterization of n-alkanethiolate monolayers adsorbed to electrochemically deposited gold nanocrystals on glassy carbon electrodes [J].
Finot, MO ;
McDermott, MT .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 488 (02) :125-132
[7]   Highly sensitive electrochemical determination of Escherichia coli density using tyrosinase-based chemically amplified biosensor [J].
Hasebe, Y ;
Yokobori, K ;
Fukasawa, K ;
Kogure, T ;
Uchiyama, S .
ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) :51-54
[8]  
Jewell WT, 2001, AM J ENOL VITICULT, V52, P219
[9]   Electroanalytical and bioelectroanalytical systems based on metal and semiconductor nanoparticles [J].
Katz, E ;
Willner, I ;
Wang, J .
ELECTROANALYSIS, 2004, 16 (1-2) :19-44
[10]   Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode [J].
Liu, SQ ;
Ju, HX .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) :177-183