Development of a tyrosinase biosensor based on gold nanoparticles-modified glassy carbon electrodes -: Application to the measurement of a bioelectrochemical polyphenols index in wines

被引:255
作者
Sanz, VC [1 ]
Mena, ML [1 ]
González-Cortés, A [1 ]
Yáñez-Sedeño, P [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
gold nanocrystal-modified glassy carbon electrodes; tyrosinase biosensors; phenolic compounds; wines;
D O I
10.1016/j.aca.2004.10.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation of a tyrosinase biosensor based on the immobilization of the enzyme onto a glassy carbon electrode modified with electrodeposited gold nanoparticles (Tyr-nAu-GCE) is reported. The enzyme immobilized by cross-linking with glutaraldehyde retains a high bioactivity on this electrode material. Under the optimized working variables (a An electrodeposition potential of -200 mV for 60 s. an enzyme loading of 457U, a detection potential of -0.10V and a 0.1 mol 1(-1) phosphate buffer solution of pH 7-4 as working medium) the biosensor exhibited a rapid response to the changes in the substrate concentration for all the phenolic compounds tested: phenol, catechol. caffeic acid, chlorogenic acid, gallic acid and protocatechualdehyde. AR.S.D. of 3.6% (n = 6) was obtained from the slope values of successive calibration plots for catechol with the same Tyr-nAu-GCE with no need to apply a cleaning procedure to the biosensor. The useful lifetime of one single biosensor was of at least 18 days, and a R.S.D. of 4.8% was obtained for the slope values of catechol calibradon plots obtained with five different biosensors. The kinetic constants and the analytical characteristics were calculated for all the phenolic compounds tested. The Tyr-nAu-GCE was applied for the estimation of the phenolic compounds content in red and white wines. A good correlation of the results (r = 0.990) was found when they were plotted versus those obtained by using the spectrophotometric method involving the Folin-Ciocalteau reagent. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 28 条
[11]   Renewable phenol biosensor based on a tyrosinase-colloidal gold modified carbon paste electrode [J].
Liu, SQ ;
Yu, JH ;
Ju, HX .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 540 :61-67
[12]   Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode [J].
Liu, SQ ;
Ju, HX .
ANALYTICAL BIOCHEMISTRY, 2002, 307 (01) :110-116
[13]   Application of colloidal gold in protein immobilization, electron transfer, and biosensing [J].
Liu, SQ ;
Leech, D ;
Ju, HX .
ANALYTICAL LETTERS, 2003, 36 (01) :1-19
[14]   Improved stability and altered selectivity of tyrosinase based graphite electrodes for detection of phenolic compounds [J].
Nistor, C ;
Emnéus, J ;
Gorton, L ;
Ciucu, A .
ANALYTICA CHIMICA ACTA, 1999, 387 (03) :309-326
[15]   ELECTROCHEMICAL STUDY OF GOLD ELECTRODES WITH ANODIC OXIDE-FILMS .1. FORMATION AND REDUCTION BEHAVIOR OF ANODIC OXIDES ON GOLD [J].
OESCH, U ;
JANATA, J .
ELECTROCHIMICA ACTA, 1983, 28 (09) :1237-1246
[16]   TYROSINASE GRAPHITE-EPOXY BASED COMPOSITE ELECTRODES FOR DETECTION OF PHENOLS [J].
ONNERFJORD, P ;
EMNEUS, J ;
MARKOVARGA, G ;
GORTON, L ;
ORTEGA, F ;
DOMINGUEZ, E .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7) :607-619
[17]   Detection of phenolic compounds in flow systems based on tyrosinase-modified reticulated vitreous carbon electrodes [J].
Peña, N ;
Reviejo, AJ ;
Pingarrón, JM .
TALANTA, 2001, 55 (01) :179-187
[18]   Improved selective electrocatalytic oxidation of phenols by tyrosinase-based carbon paste electrode biosensor [J].
Rogers, KR ;
Becker, JY ;
Cembrano, J .
ELECTROCHIMICA ACTA, 2000, 45 (25-26) :4373-4379
[19]  
Rossi JA., 1965, AM J ENOL VITICULT, V16, P144, DOI DOI 10.12691/IJEBB-2-1-5
[20]   Composite electrochemical biosensors:: a comparison of three different electrode matrices for the construction of amperometric tyrosinase biosensors [J].
Serra, B ;
Jiménez, S ;
Mena, ML ;
Reviejo, AJ ;
Pingarrón, JM .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :217-226