Pentosanpolysulfate coating of silicone reduces encrustation

被引:17
作者
Zupkas, P
Parsons, CL
Percival, C
Monga, M
机构
[1] Univ Calif San Diego, Div Urol, San Diego, CA 92103 USA
[2] Vet Affairs Med Ctr, San Diego, CA 92161 USA
关键词
D O I
10.1089/end.2000.14.483
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and Purpose: A significant problem associated with catheterization in the urinary tract is the encrustation of the catheter materials. One approach to reducing encrustation is to alter the surface properties of the catheters, We evaluated the effectiveness of coating with pentosanpolysulfate (PPS), a semisynthetic polysaccharide similar to heparin, in reducing encrustation and the foreign-body inflammatory response to silicone stents in the bladders of male New Zealand White rabbits, Materials and Methods: Sixteen rabbits were divided into three groups to receive placement in their bladders of uncoated (N = 7), PPS-coated (N = 7), or sham matrix-processed silicone rings (N = 2) via open cystotomy, After 50 days of maintenance on normal food and water, all rabbits were sacrificed, and the air-dried, unfixed silicone ring surfaces were examined by scanning electron microscopy, Bladders and remaining silicone rings were removed and preserved separately. Silicone rings, cleaned of all encrustation, were stained with toluidene blue to determine the presence or absence of PPS coating on the surface. Results: Histologic examination revealed normal tissue in bladder sections exposed to coated silicone rings and an inflammatory response in sections from bladders having uncoated silicone rings, Coating with PPS was associated with an eightfold reduction in the amount of encrustation of silicone and a marked reduction in the inflammatory response of the bladder wall to the foreign body, Conclusions: A PPS coating may be useful in reducing the encrustation of long-term indwelling silicone stents or catheters in the human urinary tract.
引用
收藏
页码:483 / 488
页数:6
相关论文
共 14 条
[1]   Surface heparinization of central venous catheters reduces microbial colonization in vitro and in vivo: Results from a prospective, randomized trial [J].
Appelgren, P ;
RansjO, U ;
Bindslev, L ;
Espersen, F ;
Larm, O .
CRITICAL CARE MEDICINE, 1996, 24 (09) :1482-1489
[2]   Biomaterials used in urology: Current issues of biocompatibility, infection, and encrustation [J].
Denstedt, JD ;
Wollin, TA ;
Reid, G .
JOURNAL OF ENDOUROLOGY, 1998, 12 (06) :493-500
[3]   CRYSTAL ADHERENCE TO URINARY CATHETER MATERIALS IN RATS [J].
FUSE, H ;
OHKAWA, M ;
NAKASHIMA, T ;
TOKUNAGA, S .
JOURNAL OF UROLOGY, 1994, 151 (06) :1703-1706
[4]   HEPARIN RELEASE FROM THERMOSENSITIVE POLYMER-COATINGS - IN-VIVO STUDIES [J].
GUTOWSKA, A ;
BAE, YH ;
JACOBS, H ;
MOHAMMAD, F ;
MIX, D ;
FEIJEN, J ;
KIM, SW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07) :811-821
[5]   FUNCTIONAL AND STRUCTURAL CHARACTERISTICS OF THE GLYCOSAMINOGLYCANS OF THE BLADDER LUMINAL SURFACE [J].
HURST, RE ;
RHODES, SW ;
ADAMSON, PB ;
PARSONS, CL ;
ROY, JB .
JOURNAL OF UROLOGY, 1987, 138 (02) :433-437
[6]   CHARACTERIZATION OF BIOFILM AND ENCRUSTATION ON URETERAL STENTS IN-VIVO [J].
KEANE, PF ;
BONNER, MC ;
JOHNSTON, SR ;
ZAFAR, A ;
GORMAN, SP .
BRITISH JOURNAL OF UROLOGY, 1994, 73 (06) :687-691
[7]   SURFACE ANTIMICROBIAL ACTIVITY OF HEPARIN-BONDED AND ANTISEPTIC-IMPREGNATED VASCULAR CATHETERS [J].
MERMEL, LA ;
STOLZ, SM ;
MAKI, DG .
JOURNAL OF INFECTIOUS DISEASES, 1993, 167 (04) :920-924
[8]   EFFECT OF DRUGS ON CRYSTAL ADHESION TO INJURED UROTHELIUM [J].
PANTAZOPOULOS, D ;
KARAGIANNAKOS, P ;
SOFRAS, F ;
KOSTAKOPOULOS, A ;
DELIVELIOTIS, C ;
DIMOPOULOS, C .
UROLOGY, 1990, 36 (03) :255-259
[9]   SUCCESSFUL THERAPY OF INTERSTITIAL CYSTITIS WITH PENTOSANPOLYSULFATE [J].
PARSONS, CL ;
MULHOLLAND, SG .
JOURNAL OF UROLOGY, 1987, 138 (03) :513-516
[10]   BLADDER-SURFACE GLYCOSAMINOGLYCANS - AN EFFICIENT MECHANISM OF ENVIRONMENTAL ADAPTATION [J].
PARSONS, CL ;
STAUFFER, C ;
SCHMIDT, JD .
SCIENCE, 1980, 208 (4444) :605-607