Commissioning and quality assurance-of the Pinnacle3 radiotherapy treatment planning system for external beam photons

被引:54
作者
Bedford, JL
Childs, PJ
Hansen, VN
Mosleh-Shirazi, MA
Verhaegen, F
Warrington, AP
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
[3] Natl Phys Lab, Ctr Ionising Radiat Metrol, Dosimetry Grp, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1259/bjr/42085182
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The commissioning of a Pinnacle(3) treatment planning system is described. Four Elekta linear accelerators were commissioned for external beam photons. Measured data were used to derive parameter values for the Pinnacle 3 beam model by (1) fitting a Monte Carlo model of the accelerator head to measured data and then extracting the parameters for the Pinnacle(3) beam model, and by (2) using the auto-modelling facility within Pinnacle(3). Both of these methods yielded dose distributions in accord with published recommendations. A separate small-field beam model, customized for an in-house compact blocking system, was also created, which satisfied appropriate acceptance criteria for stereotactically guided conformal brain treatments. Inhomogeneous, oblique, asymmetrical and irregular fields were also assessed, with calculated and measured doses agreeing to within +/-3%. Dose-volume histogram calculation was found to be accurate to within +/-5% dose or volume for a grid size of 4 mm x 4 min x 4 mm, with better accuracy being achieved for finer grids. Isocentric doses were compared between Pinnacle(3),s collapsed cone convolution algorithm and the Bentley-Milan algorithm within the Target-2 treatment planning system. Dose differences were generally less than 3% in the dose prescribed, with larger values for breast plans, where the Pinnacle(3) algorithm calculated scatter more accurately. Pelvic and thoracic plans were also verified using an anthropomorphic phantom, with local dose differences between calculated and delivered dose of up to 8%, but mainly less than 3%, and with no systematic difference. Ionization chamber verifications using START and RT-01 trial procedures demonstrated differences between calculated and measured doses of less than 2%. Following satisfactory performance in the commissioning process, Pinnacle(3) has now been introduced into routine clinical use.
引用
收藏
页码:163 / 176
页数:14
相关论文
共 34 条
[1]  
*ADAC LAB, 1999, PINN3 PHYS GUID EXT
[2]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[3]   A quantitative treatment planning study evaluating the potential of dose escalation in conformal radiotherapy of the oesophagus [J].
Bedford, JL ;
Viviers, L ;
Guzel, Z ;
Childs, PJ ;
Webb, S ;
Tait, DM .
RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) :183-193
[4]   A comparison of multileaf collimator with conformal blocks for the boost phase of dose-escalated conformal prostate radiotherapy [J].
Bedford, JL ;
Khoo, VS ;
Warrington, AP ;
Bidmead, AM ;
Webb, S ;
Deamaley, DP .
RADIOTHERAPY AND ONCOLOGY, 2001, 59 (01) :45-50
[5]  
BEDFORD JL, 2000, P 6 ANN SCI C I PHYS, P26
[6]  
Burnet N G, 1998, Clin Oncol (R Coll Radiol), V10, P1, DOI 10.1016/S0936-6555(98)80103-9
[7]   Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams [J].
De Vlamynck, K ;
Palmans, H ;
Verhaegen, F ;
De Wagter, C ;
De Neve, W ;
Thierens, H .
MEDICAL PHYSICS, 1999, 26 (09) :1874-1882
[8]   American Association of Physicists in Medicine radiation therapy committee task group 53: Quality assurance for clinical radiotherapy treatment planning [J].
Fraass, B ;
Doppke, K ;
Hunt, M ;
Kutcher, G ;
Starkschall, G ;
Stern, R ;
Van Dyke, J .
MEDICAL PHYSICS, 1998, 25 (10) :1773-1829
[9]  
HANSEN VN, 2001, RADIOTHER ONCOL, V61, pS21
[10]   TESTING A 3-D RADIATION-THERAPY PLANNING PROGRAM [J].
JACKY, J ;
WHITE, CP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :253-261