Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography

被引:25
作者
Ko, Sung Min [1 ]
Kim, Na Ra [1 ]
Kim, Dong Hun [2 ]
Song, Meong Gun [3 ]
Kim, Jin Hwan [4 ]
机构
[1] Konkuk Univ, Sch Med, Konkuk Univ Hosp, Dept Radiol, Seoul 143729, South Korea
[2] Soonchunhyang Univ, Coll Med, Bucheon Hosp, Dept Radiol, Puchon, South Korea
[3] Konkuk Univ, Sch Med, Konkuk Univ Hosp, Dept Thorac Surg, Seoul 143729, South Korea
[4] Chungnam Natl Univ, Sch Med, Chungnam Univ Hosp, Dept Radiol, Taejon, South Korea
关键词
Coronary CT angiography; Image quality; Prospective ECG-triggered; Radiation dose; Retrospective ECG-gated; HEART-RATE-VARIABILITY; TUBE CURRENT MODULATION; DUAL-SOURCE CT; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; ARTERY STENOSIS; 64-SECTION CT; PATIENT; RECONSTRUCTION; FEASIBILITY;
D O I
10.1007/s10554-009-9554-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to determine the cut-off point of the average heart rate (HR) and HR differences in obtaining diagnostic image quality using prospective electrocardiographically-triggered (PT) coronary computed tomographic angiography (CCTA) and to compare image quality and radiation dose for CCTA obtained with PT CCTA and retrospective electrocardiographically-gated (RG) CCTA. A total of 178 patients who were referred for CCTA were enrolled in the study. Two independent radiologists evaluated subjective image quality. The non-diagnostic coronary segments were 32 of 1,226 segments (2.6%) for PT CCTA and 12 of 1,346 segments (0.9%) for RG CCTA (P < 0.001). The mean image quality scores for PT CCTA and RG CCTA were 3.82 +/- 0.29 and 3.93 +/- 0.14, respectively. The mean radiation dose of patients that underwent PT CCTA was 3.83 +/- 0.84 mSv and RG CCTA 10.7 +/- 2.70 mSv. For patients who underwent PT CCTA, image quality was inversely related to HR (56.5 +/- 4.3 bpm; r = 0.38; P < 0.001) and HR differences (2.8 +/- 2.7 bpm; r = 0.49; P < 0.001). With the use of receiver operator characteristic analysis, a cut-off HR of 57 bpm (58% sensitivity, 67% specificity) and HR difference of 6 bpm (93% sensitivity, 46% specificity) were the best threshold for the prediction of diagnostic image quality. In patients with a regular, low HR, PT CCTA offers diagnostic image quality and substantially reduces effective radiation compared with the use of RG CCTA with dose modulation.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 26 条
[11]   Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: Assessment of image quality, stenosis, and radiation dose [J].
Hirai, Nobuhiko ;
Horiguchi, Jun ;
Fujioka, Chikako ;
Kiguchi, Masao ;
Yamamoto, Hideya ;
Matsuura, Noriaki ;
Kitagawa, Toshiro ;
Teragawa, Hiroki ;
Kohno, Nobuoki ;
Ito, Katsuhide .
RADIOLOGY, 2008, 248 (02) :424-430
[12]   Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography [J].
Hsieh, Jiang ;
Londt, John ;
Vass, Melissa ;
Li, Jay ;
Tang, Xiangyang ;
Okerlund, Darin .
MEDICAL PHYSICS, 2006, 33 (11) :4236-4248
[13]  
Husmann L, 2008, EUR HEART J, V29, P191, DOI 10.1093/eurheartj/ehm613
[14]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[15]   Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique [J].
Klass, Oliver ;
Jeltsch, Martin ;
Feuerlein, Sebastian ;
Brunner, Horst ;
Nagel, Hans-Dieter ;
Walker, Matthew J. ;
Brambs, Hans-Juergen ;
Hoffmann, Martin H. K. .
EUROPEAN RADIOLOGY, 2009, 19 (04) :829-836
[16]   Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography [J].
Leschka, Sebastian ;
Scheffel, Hans ;
Husmann, Lars ;
Gaemperli, Oliver ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Alkadhi, Hatem .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (06) :1583-1590
[17]   Noninvasive coronary angiography with 64-section CT: Effect of average heart rate and heart rate variability on image quality [J].
Leschka, Sebastian ;
Wildermuth, Simon ;
Boehm, Thomas ;
Desbiolles, Lotus ;
Husmann, Lars ;
Plass, Andre ;
Koepfli, Pascal ;
Schepis, Tiziano ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Alkadhi, Hatem .
RADIOLOGY, 2006, 241 (02) :378-385
[18]   Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability [J].
Matt, David ;
Scheffel, Hans ;
Leschka, Sebastian ;
Flohr, Thomas G. ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Alkadhi, Hatem .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) :567-573
[19]   Radiation dose in computed tomography of the heart [J].
Morin, RL ;
Gerber, TC ;
McCollough, CH .
CIRCULATION, 2003, 107 (06) :917-922
[20]   Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients [J].
Muehlenbruch, Georg ;
Seyfarth, Tobias ;
Soo, Chee Siong ;
Pregalathan, Namasivayam ;
Horst Mahnken, Andreas .
EUROPEAN RADIOLOGY, 2007, 17 (03) :603-609