Rapid imaging cartilage with precession and of articular steady-state free multipoint fat water separation

被引:65
作者
Reeder, SB
Pelc, NJ
Alley, MT
Gold, GE
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Palo Alto, CA 94304 USA
[2] Vet Affairs Palo Alto Hlth Care Syst, Dept Radiol, Palo Alto, CA 94304 USA
关键词
D O I
10.2214/ajr.180.2.1800357
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS. The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison. RESULTS. High-quality images of the knee with excellent fat-water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect. CONCLUSION. High-quality high-resolution images of articular cartilage with improved fat-water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat-water separation technique.
引用
收藏
页码:357 / 362
页数:6
相关论文
共 21 条
[1]   Three-point Dixon chemical-shift imaging for evaluating articular cartilage defects in the knee joint on a low-field-strength open magnet [J].
Bredella, MA ;
Losasso, C ;
Moelleken, SC ;
Huegli, RW ;
Genant, HK ;
Tirman, PFJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1371-1375
[2]   Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients [J].
Bredella, MA ;
Tirman, PFJ ;
Peterfy, CG ;
Zarlingo, M ;
Feller, JF ;
Bost, FW ;
Belzer, JP ;
Wischer, TK ;
Genant, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1073-1080
[3]  
Chapra S., 2002, NUMERICAL METHODS EN
[4]  
Disler D G, 1998, Top Magn Reson Imaging, V9, P360
[5]   MR imaging of articular cartilage [J].
Disler, DG ;
Recht, MP ;
McCauley, TR .
SKELETAL RADIOLOGY, 2000, 29 (07) :367-377
[6]   Fat-suppressed three-dimensional spoiled gradient-recalled MR imaging: Assessment of articular and physeal hyaline cartilage [J].
Disler, DG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) :1117-1123
[7]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[8]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[9]   TRANSVERSE COHERENCE IN RAPID FLASH NMR IMAGING [J].
FRAHM, J ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (02) :307-314
[10]   MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :521-530