A new automated delineation method for SPECT lung scans using adaptive dual-exponential thresholding

被引:5
作者
Wang, Alex [1 ]
Yan, Hong [1 ]
机构
[1] Univ Sydney, Sch Elect & Informat Engn, Dept Elect Engn, Kowloon, Hong Kong, Peoples R China
关键词
contour delineation; SPECT lung; pulmonary embolism; respiratory aerosol deposition;
D O I
10.1002/ima.20094
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An accurate method for delineating lung contours in single photon emission computed tomography (SPECT) is critical to respiratory studies such as pulmonary embolism (PE) and respiratory aerosol deposition. Current delineation methods are not adaptive in nature and may require a priori information on lung volumes. We have developed a dual-exponential thresholding method that solely requires SPECT scans, and is fast, accurate, and adaptive in nature. A dataset consisted of 90 patients was studied retrospectively. While most were suspected of PE, other pulmonary disorders were also present. SPECT ventilation scans were obtained after inhalation of similar to 40 MBq of 99mTc-Technegas. Examination of the corresponding natural logarithmically transformed histograms revealed dual exponential functions like pattern. Adaptive thresholds were found as the intercept between the two exponential functions. 350 Monte Carlo simulations representative of normal ly-vent i lated scans with varying counts were used to quantitatively measure and evaluate the method. Our method correctly delineated lung volumes to above 97% agreement for 310 of the 350 Monte Carlo simulations with maximum count values greater than or equal to 31. The 40 low-count simulations were included purely as extreme cases. For real patient scenario, an experienced physician was called upon to visually delineate a sample of 50 actual patient scans, and these delineated lung volumes were used as gold standard and compared with those delineated using our method. Our results had an average of 96% agreement. (c) 2007 Wiley Periodicals, Inc.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 34 条
[11]   Three-dimensional imaging of aerosol deposition [J].
Fleming, JS ;
Conway, JH .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (02) :147-153
[12]  
GOTTSCHALK A, 1993, J NUCL MED, V34, P1109
[13]  
GOTTSCHALK A, 1993, J NUCL MED, V34, P1119
[14]  
Hoofs JC, 1999, J NUCL MED, V40, P1745
[15]  
Howarth DM, 1999, J NUCL MED, V40, P579
[16]  
Jentzen W, 2007, J NUCL MED, V48, P108
[17]  
LOGUS JW, 1984, J CAN ASSOC RADIOL, V35, P133
[18]   Validation of a new automated method for analysis of gated-SPECT images [J].
Lomsky, M ;
Richter, J ;
Johansson, L ;
Hoilund-Carlsen, PF ;
Edenbrandt, L .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (03) :139-145
[19]   A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model [J].
Lomsky, M ;
Richter, J ;
Johansson, L ;
El-Ali, H ;
Åström, K ;
Ljungberg, M ;
Edenbrandt, L .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (04) :234-240
[20]   Single-photon emission tomography of a computerised model of pulmonary embolism [J].
Magnussen, JS ;
Chicco, P ;
Palmer, AW ;
Bush, V ;
Mackey, DW ;
Storey, G ;
Magee, M ;
Bautovich, G ;
Van der Wall, H .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (11) :1430-1438