Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: Initial experience

被引:41
作者
Koktzoglou, Ioannis
Chung, Yiu-Cho
Carroll, Timothy J.
Simonetti, Orlando P.
Morasch, Mark D.
Li, Debiao
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Surg, Div Vasc Surg, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, Evanston, IL USA
[4] Siemens Med Solut, Chicago, IL USA
[5] Ohio State Univ, Coll Med & Publ Hlth, Dept Cardiovasc Med & Radiol, Columbus, OH 43210 USA
关键词
D O I
10.1148/radiol.2431060310
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This HIPAA-compliant study had institutional review board approval. Informed consent was obtained. The purpose was to prospectively evaluate a segmented three-dimensional (3D) double inversion recovery (DIR)-prepared steady-state free precession (SSFP) magnetic resonance (MR) imaging sequence for fast high-spatial-resolution black-blood carotid arterial wall imaging. Carotid wall-lumen contrast-to-noise ratio (CNR) obtained with this sequence was compared with those obtained with two-dimensional (2D) single-and multisection black-blood fast spin-echo (SE) sequences. MR imaging of both carotid artery bifurcations over 3 cm of transverse coverage was performed in eight volunteers (seven men, one woman; age range, 26 - 56 years) with no known history of carotid artery disease. Adjusted for section thickness and imaging time per section, higher effective mean CNR was achieved with segmented 3D DIR-prepared SSFP than with single-section 2D DIR-prepared fast SE or multisection 2D saturation-band fast SE (P < .05). Segmented 3D DIR-prepared SSFP enables black-blood carotid arterial wall MR imaging with contiguous thin-section coverage and greater imaging speed and effective CNR than conventional 2D fast SE techniques.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 29 条
[1]   Bilateral symmetry of human carotid artery atherosclerosis [J].
Adams, GJ ;
Simoni, DM ;
Bordelon, CB ;
Vick, GW ;
Kimball, KT ;
Insull, W ;
Morrisett, JD .
STROKE, 2002, 33 (11) :2575-2580
[2]   Juxtalumenal location of plaque necrosis and neoformation in symptomatic carotid stenosis [J].
Bassiouny, HS ;
Sakaguchi, Y ;
Mikucki, SA ;
McKinsey, JF ;
Piano, G ;
Gewertz, BL ;
Glagov, S .
JOURNAL OF VASCULAR SURGERY, 1997, 26 (04) :585-594
[3]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[4]   Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging [J].
Cai, JM ;
Hastukami, TS ;
Ferguson, MS ;
Small, R ;
Polissar, NL ;
Yuan, C .
CIRCULATION, 2002, 106 (11) :1368-1373
[5]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[6]   Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement [J].
Crowe, LA ;
Gatehouse, P ;
Yang, GZ ;
Mohiaddin, RH ;
Varghese, A ;
Charrier, C ;
Keegan, J ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) :572-580
[7]   FAST SELECTIVE BLACK BLOOD MR IMAGING [J].
EDELMAN, RR ;
CHIEN, D ;
KIM, D .
RADIOLOGY, 1991, 181 (03) :655-660
[8]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[9]   TrueFISP - technical considerations and cardiovascular applications [J].
Fuchs, F ;
Laub, G ;
Othomo, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 46 (01) :28-32
[10]   Characterization and reduction of the transient response in steady-state MR imaging [J].
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :149-158