Correlation of lung tumor motion with external surrogate indicators of respiration

被引:273
作者
Hoisak, JDP
Sixel, KE
Tirona, R
Cheung, PCF
Pignol, JP
机构
[1] Toronto Sunnibrook Reg Canc Ctr, Dept Phys Med, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2004年 / 60卷 / 04期
关键词
lung cancer; tumor motion; respiration surrogates;
D O I
10.1016/j.ijrobp.2004.07.681
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the correlation of respiratory volume and abdominal displacement with tumor motion as seen with X-ray fluoroscopy. Measurements throughout the patient's treatment course allowed an assessment of the interfractional reproducibility of this correlation. Methods and Materials: Data were acquired from 11 patients; 5 were studied over multiple days. Measurements of respiratory volume by spirometry and abdominal displacement by a real-time position tracking system were correlated to simultaneously acquired X-ray fluoroscopy measurements of superior-inferior tumor displacement. The linear correlation coefficient was computed for each data acquisition. The phase relationship between the surrogate and tumor signals was estimated through cross-correlation delay analysis. Results: Correlation coefficients ranged from very high to very low (0.99-0.39, p < 0.0001). The correlation between tumor displacement and respiratory volume was higher and more reproducible from day to day than between tumor displacement and abdominal displacement. A nonzero phase relationship was observed in nearly all patients (-0.65 to +0.50 s). This relationship was observed to vary over inter- and intrafractional time scales. Only 1 of 5 patients studied over multiple days had a consistent relationship between tumor motion and either surrogate. Conclusions: Respiratory volume has a more reproducible correlation with tumor motion than does abdominal displacement. If forming a tumor-surrogate prediction model from a limited series of observations, the use of surrogates to guide treatment might result in geographic miss. (C) 2004 Elsevier Inc.
引用
收藏
页码:1298 / 1306
页数:9
相关论文
共 30 条
[21]  
2-2
[22]   Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor [J].
Shirato, H ;
Shimizu, S ;
Kitamura, K ;
Nishioka, T ;
Kagei, K ;
Hashimoto, S ;
Aoyama, H ;
Kunieda, T ;
Shinohara, N ;
Dosaka-Akita, H ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :435-442
[23]  
SHIRATO H, 2003, INT J RADIAT ONCOL, V56, P40
[24]   Digital fluoroscopy to quantify lung tumor motion: Potential for patient-specific planning target volumes [J].
Sixel, KE ;
Ruschin, M ;
Tirona, R ;
Cheung, PCF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :717-723
[25]   Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function [J].
Stevens, CW ;
Munden, RF ;
Forster, KM ;
Kelly, JF ;
Liao, ZX ;
Starkschall, G ;
Tucker, S ;
Komaki, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01) :62-68
[26]   Acquiring a four-dimensional computed tomography dataset using an external respiratory signal [J].
Vedam, SS ;
Keall, PJ ;
Kini, VR ;
Mostafavi, H ;
Shukla, HP ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (01) :45-62
[27]   Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker [J].
Vedam, SS ;
Kini, VR ;
Keall, PJ ;
Ramakrishnan, V ;
Mostafavi, H ;
Mohan, R .
MEDICAL PHYSICS, 2003, 30 (04) :505-513
[28]   Determining parameters for respiration-gated radiotherapy [J].
Vedam, SS ;
Keall, PJ ;
Kini, VR ;
Mohan, R .
MEDICAL PHYSICS, 2001, 28 (10) :2139-2146
[29]   The use of active breathing control (ABC) to reduce margin for breathing motion [J].
Wong, JW ;
Sharpe, MB ;
Jaffray, DA ;
Kini, VR ;
Robertson, JM ;
Stromberg, JS ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (04) :911-919
[30]   Application of the spirometer in respiratory gated radiotherapy [J].
Zhang, TZ ;
Keller, H ;
O'Brien, MJ ;
Mackie, TR ;
Paliwal, B .
MEDICAL PHYSICS, 2003, 30 (12) :3165-3171