Retention mechanism of poly(ethylene oxide) in reversed-phase and normal-phase liquid chromatography

被引:56
作者
Cho, D
Park, S
Hong, J
Chang, T [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Chem, Pohang 790784, South Korea
[2] Pohang Univ Sci & Technol, Polymer Res Inst, Pohang 790784, South Korea
基金
新加坡国家研究基金会;
关键词
retention mechanism; temperature effects; poly(ethylene oxide);
D O I
10.1016/S0021-9673(02)01953-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The retention behavior of low- and high-molecular-mass poly(ethylene oxide) (PEO) in reversed-phase (RP) and normal-phase (NP) liquid chromatography was investigated. In RPLC using a C-18 bonded silica stationary phase and an acetonitrile-water mixture mobile phase, the sorption process of PEO to the stationary phase showed DeltaHdegrees > 0 and DeltaSdegrees > 0. Therefore, PEO retention in RPLC separation is an energetically unfavorable, entropy-driven process, which results in an increase of PEO retention as the temperature increases. In addition, at the enthalpy-entropy compensation point the elution volume of PEO was very different from the column void volume. These observations are quite different from the RPLC retention behavior of many organic polymers. The peculiar retention behavior of PEO in RPLC separation can be understood in terms of the hydrophobic interaction of this class of typical amphiphilic compounds with the non-polar stationary phase, on the one hand, and with the aqueous mobile phase, on the other. The entropy gain due to the release of the solvated water molecules from the PEO chain and the stationary phase is believed to be responsible for the entropy-driven separation process. On the other hand, in NPLC using an amino-bonded silica stationary phase and an acetonitrile-water mixture mobile phase, PEO showed normal enthalpy-driven retention behavior: DeltaHdegrees < 0 and DeltaSdegrees < 0, with the retention decreasing with increasing temperature and PEO eluting near the column void volume at the enthalpy-entropy compensation point. Therefore, high-resolution temperature gradient NPLC separation of high-molecular-mass PEO samples can be achieved with relative ease. The molecular mass distribution of high-molecular-mass PEO was found to be much narrower than that measured by size-exclusion chromatography. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 42 条
[11]   Simultaneous separation of nonionic surfactants and polyethylene glycols by reversed phase high performance liquid chromatography [J].
Kamiusuki, T ;
Monde, T ;
Omae, K ;
Morioka, K ;
Konakahara, T .
CHROMATOGRAPHIA, 2000, 51 (7-8) :390-396
[12]   Polymer molecular weight characterization by temperature gradient high performance liquid chromatography [J].
Lee, HC ;
Chang, TY .
POLYMER, 1996, 37 (25) :5747-5749
[13]   Characterization of poly(L-lactide)-block-poly(ethylene oxide)-block-poly(L-lactide) triblock copolymer by liquid chromatography at the critical condition and by MALDI-TOF mass spectrometry [J].
Lee, HJ ;
Chang, TY ;
Lee, DS ;
Shim, MS ;
Ji, HN ;
Nonidez, WK ;
Mays, JW .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1726-1732
[14]   Molecular weight distribution of polystyrene made by anionic polymerization [J].
Lee, W ;
Lee, H ;
Cha, J ;
Chang, T ;
Hanley, KJ ;
Lodge, TP .
MACROMOLECULES, 2000, 33 (14) :5111-5115
[15]   Temperature gradient interaction chromatography of low molecular weight polystyrene [J].
Lee, W ;
Lee, HC ;
Park, T ;
Chang, T ;
Chang, JY .
POLYMER, 1999, 40 (26) :7227-7231
[16]   Characterization of poly(methyl methacrylate) by temperature gradient interaction chromatography with on-line light scattering detection [J].
Lee, W ;
Lee, HC ;
Chang, TY ;
Kim, SB .
MACROMOLECULES, 1998, 31 (02) :344-348
[17]  
Lee W, 2000, MACROMOL CHEM PHYSIC, V201, P320, DOI 10.1002/(SICI)1521-3935(20000201)201:3<320::AID-MACP320>3.3.CO
[18]  
2-W
[19]   Characterization of polystyrene and polyisoprene by normal-phase temperature gradient interaction chromatography [J].
Lee, W ;
Cho, D ;
Chun, BO ;
Chang, T ;
Ree, M .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :51-60
[20]   ANALYSIS AND PURIFICATION OF MODIFIED METHOXY(POLYETHYLENE GLYCOL) COMPOUNDS OF SIMILAR MOLECULAR-MASS BY HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LEISTER, WH ;
WEANER, LE ;
WALKER, DG .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (02) :369-376