Acidic and neutral drugs screen in blood with quantitation using microbore high-performance liquid chromatography diode array detection and capillary gas chromatography flame ionization detection

被引:33
作者
Lo, DST [1 ]
Chao, TC [1 ]
Ng-Ong, SE [1 ]
Yao, YJ [1 ]
Koh, TH [1 ]
机构
[1] Inst Sci & Forens Med, Singapore 169078, Singapore
关键词
high performance liquid chromatography; diode array detection; acidic drugs; neutral drugs; blood;
D O I
10.1016/S0379-0738(97)00170-9
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Blood previously acidified with aqueous saturated ammonium chloride solution was extracted with ethyl acetate. The dried extract was subjected to acetonitrile-hexane partition. The acetonitrile portion was analysed for the presence of acidic and neutral drugs by HPLC-DAD (200 mmX2.1 mm I.D. microbore ODS-Hypersil column) and GC-FID (25 m narrow-boreX0.25 mm I.D. HP-5 column with 0.33 mu m film thickness). The protocol was found to be suitable for both clinical toxicology (including emergency toxicology) and postmortem toxicology. At least 66 drugs of interest were unequivocally identified by RRTs (HPLC) and UV spectra (DAD) match while another 12 were unequivocally identified by double RRTs match (HPLC and GC). Quantitation was facilitated by incorporating calibration blood standards in each assay batch. The five drugs most commonly encountered in clinical blood specimens (1150 cases) were: paracetamol (47.4% of the cases); chlormezanone (6.6%), theophylline (1.74%), naproxen (1.65%) and mefenamic acid (1.56%). The following drugs were detected in toxicologically significant quantities in postmortem blood specimens (245 cases): phenobarbitone (1.22% of the cases), naproxen (0.82%), chlormezanone (0.82%), theophylline (0.82%), carbamazepine (0.41%) and paracetamol (0.41%). (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:205 / 214
页数:10
相关论文
共 26 条
[11]   ANALYSIS OF ACIDIC-NEUTRAL DRUGS IN HUMAN-SERUM BY FUSED-SILICA CAPILLARY CHROMATOGRAPHY [J].
DUNPHY, MJ ;
PANDYA, MK .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (06) :317-319
[12]   GAS-CHROMATOGRAPHIC SCREENING-PROCEDURE FOR ACID AND NEUTRAL-DRUGS IN BLOOD [J].
FOERSTER, EH ;
DEMPSEY, J ;
GARRIOTT, JC .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1979, 3 (03) :87-91
[13]   A RAPID EXTRACTION METHOD FOR ACIDIC DRUGS IN HEMOLYZED BLOOD [J].
FORD, B ;
VINE, J ;
WATSON, TR .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1983, 7 (03) :116-118
[14]  
GILL R, 1982, J CHROMATOGR, V233, P438, DOI 10.1016/S0378-4347(00)81783-1
[15]   ROLE OF THE TOXICOLOGY LABORATORY IN THE TREATMENT OF ACUTE-POISONING [J].
HEPLER, BR ;
SUTHEIMER, CA ;
SUNSHINE, I .
MEDICAL TOXICOLOGY AND ADVERSE DRUG EXPERIENCE, 1986, 1 (01) :61-75
[16]   HPLC PHOTODIODE ARRAY UV DETECTION FOR TOXICOLOGICAL DRUG ANALYSIS [J].
HILL, DW ;
LANGNER, KJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (2-3) :377-409
[17]   IDENTIFICATION POWER OF A STANDARDIZED HPLC-DAD SYSTEM FOR SYSTEMATIC TOXICOLOGICAL ANALYSIS [J].
MAIER, RD ;
BOGUSZ, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (02) :79-83
[18]   SCREENING FOR DRUGS IN CLINICAL TOXICOLOGY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - IDENTIFICATION OF BARBITURATES BY POST-COLUMN IONIZATION AND DETECTION BY A MULTIPLACE PHOTODIODE ARRAY SPECTROPHOTOMETER [J].
MINDER, EI ;
SCHAUBHUT, R ;
VONDERSCHMITT, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 428 (02) :369-376
[19]  
MOFFAR AC, 1986, CLARKES ISOLATION ID
[20]   RAPID EXTRACTION OF ANTIINFLAMMATORY DRUGS IN WHOLE-BLOOD FOR HPLC ANALYSIS [J].
MOORE, CM ;
TEBBETT, IR .
FORENSIC SCIENCE INTERNATIONAL, 1987, 34 (1-2) :155-158