Performance of a pentafluorophenylpropyl stationary phase for the electrospray ionization high-performance liquid chromatography-mass spectrometry-mass spectrometry assay of cocaine and its metabolite ecgonine methyl ester in human urine

被引:41
作者
Needham, SR
Jeanville, PM
Brown, PR
Estape, ES
机构
[1] Pfizer Inc, Div Cent Res, Drug Metab Technol Grp, Groton, CT 06340 USA
[2] Univ Rhode Isl, Dept Chem, Kingston, RI 02881 USA
[3] Univ Puerto Rico, Coll Hlth Related Profess, San Juan, PR 00936 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 748卷 / 01期
关键词
stationary phases; LC; cocaine; ecgonine methyl ester; pentafluorophenylpropyl;
D O I
10.1016/S0378-4347(00)00271-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A pentafluorophenylpropyl (PFPP) bonded silica column has been used for the high-performance liquid chromatography-electrospray ionization-mass spectrometry-mass spectrometry assay (HPLC-ESI-MS-MS) of cocaine (COC) and its metabolite, ecgonine methyl ester (EME) in human urine. COC and EME were used as model basic solutes to demonstrate that a PFPP phase yields excellent results for the assay and validation of drugs in biological fluids, The assay was linear over three orders of magnitude (1.0-1000 ng/ml) and precision and accuracy of the assay was 4 and 15%, respectively. The limit of detection (LOD) for COC and EME was 1.6 and 2.8 pg on column, respectively. In addition, only a simple 1:10 dilution of the urine was necessary for the sample preparation procedure thus saving time on a laborious extraction step. The major advantage of the PFPP phase was the enhancement of the ESI-MS signal by providing good retention and good peak shape of COC and EME with a mobile phase of 90% acetonitrile. The MS signal for COC was a factor of 12 times greater on the PFPP phase than on the C-18 phase. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:77 / 87
页数:11
相关论文
共 25 条
[11]   FROM IONS IN SOLUTION TO IONS IN THE GAS-PHASE - THE MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY [J].
KEBARLE, P ;
TANG, L .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :A972-A986
[12]   Determination of cocaine and its metabolites in serum microsamples by high-performance liquid chromatography and its application to pharmacokinetics in rats [J].
Ma, F ;
Zhang, J ;
Lau, CE .
JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (02) :307-312
[13]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[14]   EVALUATION OF REVERSED-PHASE COLUMNS FOR THE ANALYSIS OF VERY BASIC COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - APPLICATION TO THE DETERMINATION OF THE TOBACCO ALKALOIDS [J].
MCCALLEY, DV .
JOURNAL OF CHROMATOGRAPHY, 1993, 636 (02) :213-220
[15]   Determination of drugs of abuse in blood [J].
Moeller, MR ;
Steinmeyer, S ;
Kraemer, T .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (01) :91-109
[16]   Optimized stationary phases for the high-performance liquid chromatography-electrospray ionization mass spectrometric analysis of basic pharmaceuticals [J].
Needham, SR ;
Brown, PR ;
Duff, K ;
Bell, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :159-170
[17]  
Needham SR, 1999, RAPID COMMUN MASS SP, V13, P2231, DOI 10.1002/(SICI)1097-0231(19991130)13:22<2231::AID-RCM779>3.0.CO
[18]  
2-4
[19]   Sensitive and specific high-performance liquid chromatographic assay with ultraviolet detection for the determination of cocaine and its metabolites in rat plasma [J].
Pan, WJ ;
Hedaya, MA .
JOURNAL OF CHROMATOGRAPHY B, 1997, 703 (1-2) :129-138
[20]   Capillary column supercritical fluid chromatography-atmospheric pressure ionisation mass spectrometry -: Interface performance of atmospheric pressure chemical ionisation and electrospray ionisation [J].
Sjöberg, PJR ;