Toward continuous glucose monitoring with planar modified biosensors and microdialysis - Study of temperature, oxygen dependence and in vivo experiment

被引:27
作者
Ricci, Francesco
Caprio, Felice
Poscia, Alessandro
Valgimigli, Francesco
Messeri, Dirnitri
Lepori, Elena
Dall'Oglio, Giorgio
Palleschi, Giuseppe
Moscone, Danila
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] A Menarini Mfg, Logist & Serv Diagnost Div, Prod Dept A, Pisa, Italy
[3] ESLAB Srl, Milan, Italy
关键词
glucose; continuous monitoring; screen printed; mediator; microdialysis;
D O I
10.1016/j.bios.2006.08.041
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Glucose biosensors based on the use of planar screen-printed electrodes modified with an electrochemical mediator and with glucose oxidase have been optimised for their application in the continuous glucose monitoring in diabetic patients. A full study of their operative stability and temperature dependence has been accomplished, thus giving useful information for in vivo applications. The effect of dissolved oxygen concentration in the working solution was also studied in order to evaluate its effect on the linearity of the sensors. Glucose monitoring performed with serum samples was performed to evaluate the effect of matrix components on operative stability and demonstrated an efficient behaviour for 72 h of continuous monitoring. Finally, these studies led to a sensor capable of detecting glucose at concentrations as low as 0.04 mM and with a good linearity up to 2.0 mM (at 37 degrees C) with an operative stability of ca. 72 h, thus demonstrating the possible application of these sensors for continuous glucose monitoring in conjunction with a microdialysis probe. Moreover, preliminary in vivo experiments for ca. 20 h have demonstrated the feasibility of this system. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2032 / 2039
页数:8
相关论文
共 24 条
[1]   A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm [J].
Aussedat, B ;
Thome-Duret, V ;
Reach, G ;
Lemmonier, F ;
Klein, JC ;
Hu, Y ;
Wilson, GS .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) :1061-1071
[2]   Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring [J].
Aussedat, B ;
Dupire-Angel, M ;
Gifford, R ;
Klein, JC ;
Wilson, GS ;
Reach, G .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04) :E716-E728
[3]   First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system [J].
Caduff, A ;
Hirt, E ;
Feldman, Y ;
Ali, Z ;
Heinemann, L .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) :209-217
[4]   Does continuous glucose monitoring have clinical utility in contemporary management of diabetes? [J].
Cameron, FJ ;
Ambler, GR .
JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2004, 40 (03) :79-84
[5]  
KERNER W, 2001, EXP CLIN ENDOCRINOL, V2, P341
[6]  
Khalil Omar S, 2004, Diabetes Technol Ther, V6, P660, DOI 10.1089/dia.2004.6.660
[7]   INVIVO BEHAVIOR OF HYPODERMICALLY IMPLANTED MICROFABRICATED GLUCOSE SENSORS [J].
KOUDELKA, M ;
ROHNERJEANRENAUD, F ;
TERRETTAZ, J ;
BOBBIONIHARSCH, E ;
DEROOIJ, NF ;
JEANRENAUD, B .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) :31-36
[8]   Continuous subcutaneous glucose monitoring in diabetic patients - A multicenter analysis [J].
Maran, A ;
Crepaldi, C ;
Tiengo, A ;
Grassi, G ;
Vitali, E ;
Pagano, G ;
Bistoni, S ;
Calabrese, G ;
Santeusanio, F ;
Leonetti, F ;
Ribaudo, M ;
Di Mario, U ;
Annuzzi, G ;
Genovese, S ;
Riccardi, G ;
Previti, M ;
Cucinotta, D ;
Giorgino, F ;
Bellomo, A ;
Giorgino, R ;
Poscia, A ;
Varalli, M .
DIABETES CARE, 2002, 25 (02) :347-352
[9]  
Mastrototaro J, 1999, J PEDIATR ENDOCR MET, V12, P751
[10]   ON LINE CONTINUOUS MONITORING OF SUBCUTANEOUS TISSUE GLUCOSE IN MEN BY COMBINING PORTABLE GLUCOSENSOR WITH MICRODIALYSIS [J].
MEYERHOFF, C ;
BISCHOF, F ;
STERNBERG, F ;
ZIER, H ;
PFEIFFER, EF .
DIABETOLOGIA, 1992, 35 (11) :1087-1092