An integrated PET-SPECT small animal imager: preliminary results

被引:41
作者
Del Guerra, A
Damiani, C
Di Domenico, G
Motta, A
Giganti, M
Marchesini, R
Piffanelli, A
Sabba, N
Sartori, L
Zavattini, G
机构
[1] Univ Pisa, Dept Phys, I-56100 Pisa, Italy
[2] Ist Nazl Fis Nucl, Pisa, Italy
[3] Univ Ferrara, Dept Phys, I-44100 Ferrara, Italy
[4] Ist Nazl Fis Nucl, Ferrara, Italy
[5] Univ Ferrara, Dept Clin Expt Med, I-44100 Ferrara, Italy
关键词
D O I
10.1109/23.873012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have successfully built and characterised a small animal PET based on 4 rotating detectors with a spatial resolution < 2 mm over its field of view and a sensitivity of 640 cps/mu Ci at the centre. The scanner is based on four matrices of 400 YAP:Ce finger crystals (2x2x30 mm(3) each) coupled to Position Sensitive PhotoMultipliers (Hamamatsu R2486-06.) We have now applied two high resolution collimators to two opposite detectors, hence realising an integrated PET-SPECT scanner for small animals. The collimators are made of lead with 20 mm long, 0.6 mm hexagonal holes with 0.15mm septa. The read-out and data acquisition system are handled by NIM-CAMAC standard electronics. The Field Of View (FOV) of the tomograph has a diameter of 4 cm and an axial length of 4 cm in both PET and SPECT configuration which is appropriate for mice and rat studies.
引用
收藏
页码:1537 / 1540
页数:4
相关论文
共 11 条
[1]   THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH [J].
BLOOMFIELD, PM ;
RAJESWARAN, S ;
SPINKS, TJ ;
HUME, SP ;
MYERS, R ;
ASHWORTH, S ;
CLIFFORD, KM ;
JONES, WF ;
BYARS, LG ;
YOUNG, J ;
ANDREACO, M ;
WILLIAMS, CW ;
LAMMERTSMA, AA ;
JONES, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) :1105-1126
[2]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[3]  
CUTLER PD, 1992, J NUCL MED, V33, P595
[4]   Measurement of absolute light yield and determination of a lower limit for the light attenuation length for YAP:Ce crystal [J].
Del guerra, A ;
de Notaristefani, F ;
Di Domenico, G ;
Zavattini, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2415-2418
[5]   YAP-PET:: first results of a small animal Positron Emission Tomograph based on YAP:Ce finger crystals [J].
Del Guerra, A ;
Di Domenico, G ;
Scandola, M ;
Zavattini, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :3105-3108
[6]   Image noise properties of a phosphor-coated CCD X-ray detector [J].
Gambaccini, M ;
Taibi, A ;
Baldelli, P ;
Del Guerra, A ;
Tuffanelli, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :508-510
[7]  
HICHWA R, 1994, J NUCL MED, V35, P1396
[8]  
MALATESTA T, 1998, NUCL PHYS B, V61, P644
[9]  
MARRIOTT CJ, 1994, J NUCL MED, V35, P1390
[10]  
WEBB S, MED SCI SERIES I PHY, P162