Electrochemical characterisation of liquid|liquid microinterface arrays

被引:45
作者
Wilke, S [1 ]
Osborne, MD
Girault, HH
机构
[1] Univ Halle Wittenberg, Fachbereich Chem, Inst Analyt & Umweltchem, D-06099 Halle, Germany
[2] Ecole Polytech Fed Lausanne, Lab Electrochim, CH-1015 Lausanne, Switzerland
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1997年 / 436卷 / 1-2期
关键词
D O I
10.1016/S0022-0728(97)00323-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Arrays of water-nitrobenzene microinterfaces have been realised by separating the two liquid phases with a polymer film, in which 100 microholes were drilled using a UV laser photoablation technique. The microholes were arranged in a square pattern with center-to-center separations of 20 to 200 mu m. The diameter of the microholes was 10, 5 and similar to 0.5 mu m. Cyclic voltammetry, chronoamperometry and measurements in an electrochemical flow cell were used to characterise the electrochemical behavior of the arrays. The dependence of the chronoamperometric response on the center-to-center distance and diameter of the microinterfaces was investigated for times between 1 and 400 s after the application of the potential step. Unlike single microinterfaces, a steady-state current is observed only for very long times and is attributable to natural convection processes as for electrodes of larger dimensions. The plot of the inverse current versus the square root of the time reveals, that the chronoamperometric response for medium times (about 1 to 20 s) is governed both by planar diffusion normal to the plane of the array and by hemispheric diffusion to the individual microinterfaces. A simple model is proposed which describes the chronoamperometric response for the medium time range. When the arrays are used in a flow-through electrochemical cell, no dependence of the current on the flow rate is observed as long as the volume flow rate is less than a limiting value. For flow rates above this limiting value, the logarithm of the steady-state current depends linearly on the logarithm of the volume flow rate, as for conventional electrodes of large dimensions. The limiting value depends on distance and diameter of the microinterfaces and was of the order of 1 ml/min. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 23 条
  • [11] THE LIQUID-LIQUID MICRO-INTERFACE FOR THE AMPEROMETRIC DETECTION OF UREA
    OSBORNE, MD
    GIRAULT, HH
    [J]. ELECTROANALYSIS, 1995, 7 (08) : 714 - 721
  • [12] OSBORNE MD, 1995, ELECTROANAL, V7, P175
  • [13] ENSEMBLES OF MICROELECTRODES - A DIGITAL-SIMULATION
    RELLER, H
    KIROWAEISNER, E
    GILEADI, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 138 (01): : 65 - 77
  • [14] DIFFUSION TO ENSEMBLES OF MICROELECTRODES
    SCHARIFKER, BR
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 240 (1-2): : 61 - 76
  • [15] CHRONOAMPEROMETRIC CURRENT AT FINITE DISK ELECTRODES
    SHOUP, D
    SZABO, A
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 140 (02): : 237 - 245
  • [16] CHRONOAMPEROMETRY AT AN ENSEMBLE OF MICRODISK ELECTRODES
    SHOUP, D
    SZABO, A
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 160 (1-2) : 19 - 26
  • [17] ION TRANSFER-REACTIONS ACROSS A LIQUID LIQUID INTERFACE SUPPORTED ON A MICROPIPETTE TIP
    TAYLOR, G
    GIRAULT, HHJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 208 (01): : 179 - 183
  • [18] DIGITAL-SIMULATION OF CHARGE-TRANSFER TO AN ULTRAMICRODISC INTERFACE
    TAYLOR, G
    GIRAULT, HH
    MCALEER, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 293 (1-2): : 19 - 44
  • [19] THOMAS DW, 1992, LASER ABLATION ELECT, V4, P221
  • [20] GALVANI POTENTIAL SCALES FOR WATER-NITROBENZENE AND WATER-1,2-DICHLOROETHANE INTERFACES
    WANDLOWSKI, T
    MARECEK, V
    SAMEC, Z
    [J]. ELECTROCHIMICA ACTA, 1990, 35 (07) : 1173 - 1175