Transfemoral catheterization of carotid arteries with real-time MR imaging guidance in pigs

被引:24
作者
Feng, L
Dumoulin, CL
Dashnaw, S
Darrow, RD
Guhde, R
DeLaPaz, RL
Bishop, PL
Pile-Spellman, J
机构
[1] Columbia Univ, Dept Radiol, New York, NY 10032 USA
[2] GE Co, Global Res Ctr, Schenectady, NY 12301 USA
关键词
D O I
10.1148/radiol.2341031951
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
All procedures and protocols were approved by the institutional animal care and use committee of Columbia University. To determine whether transfemoral catheterization of the carotid arteries can be performed entirely with real-time magnetic resonance (MR) imaging guidance, the authors catheterized the carotid arteries in six domestic pigs by using, active-tracking catheters and guidewires and MR tracking software created for neurovascular procedures. The carotid arteries were successfully catheterized 24 times, on average within 5 minutes after insertion of the catheter into the femoral artery. Results demonstrated the feasibility of performing transfemoral catheterization of the carotid arteries with active MR tracking devices in a conventional MR imaging unit. (C) RSNA, 2004.
引用
收藏
页码:551 / 557
页数:7
相关论文
共 40 条
[1]  
Aoki S, 1999, Radiat Med, V17, P251
[2]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[3]   Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions [J].
Bakker, CJ ;
Hoogeveen, RM ;
Weber, J ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WP .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :816-820
[4]  
Bartels LW, 2000, J MAGN RESON IMAGING, V12, P599, DOI 10.1002/1522-2586(200010)12:4<599::AID-JMRI13>3.3.CO
[5]  
2-Z
[6]   Carotid angioplasty and stenting versus carotid endarterectomy: Randomized trial in a community hospital [J].
Brooks, WH ;
McClure, RR ;
Jones, MR ;
Coleman, TC ;
Breathitt, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (06) :1589-1595
[7]   Real-time MR guidance for inferior vena cava filter placement in an animal model [J].
Bücker, A ;
Neuerburg, JM ;
Adam, GB ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Günther, RW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (06) :753-756
[8]  
Buecker A, 2000, J MAGN RESON IMAGING, V12, P616, DOI 10.1002/1522-2586(200010)12:4<616::AID-JMRI15>3.0.CO
[9]  
2-F
[10]   Endovascular procedures under near-real-time magnetic resonance imaging guidance:: An experimental feasibility study [J].
Dion, YM ;
El Kadi, HB ;
Boudoux, C ;
Gourdon, J ;
Chakfé, N ;
Traoré, A ;
Moisan, C .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (05) :1006-1014