Three-dimensional coronary MR angiography using zonal echo planar imaging

被引:39
作者
Yang, GZ [1 ]
Gatehouse, PD [1 ]
Keegan, J [1 ]
Mohiaddin, RH [1 ]
Firmin, DN [1 ]
机构
[1] Royal Brompton Hosp, Magnet Resonance Unit, London SW3 6NP, England
关键词
3D coronary angiography; 2D spatially selective excitation; navigator echo; echo-planar imaging;
D O I
10.1002/mrm.1910390521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using an adapted two-dimensional spatially selective RF excitation scheme, a novel yet practical three-dimensional (3D) zonal echo-planar imaging technique for MR coronary angiography has been developed. The robustness of the technique compared with the two-dimensional (2D) segmented fast low angle shot (FLASH) method was evaluated using the right coronary artery images of 16 asymptomatic volunteers with a 0.5-T mobile scanner. Each 3D acquisition required multiple breath-holds, and real-time navigator echoes were used to ensure consistent breath-holding. Advantages of the technique include an improved signal-to-noise ratio, clearer depiction of tortuous coronary vessels due to decreased partial volume effects, and reduced motion blurring by the use of a short echo-planar readout.
引用
收藏
页码:833 / 842
页数:10
相关论文
共 39 条
[31]   CORONARY ANGIOGRAPHY USING FAST SELECTIVE INVERSION RECOVERY [J].
WANG, SJ ;
HU, BS ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :417-423
[32]   CORONARY MRI WITH A RESPIRATORY FEEDBACK MONITOR - THE 2D IMAGING CASE [J].
WANG, Y ;
CHRISTY, PS ;
KOROSEC, FR ;
ALLEY, MT ;
GRIST, TM ;
POLZIN, JA ;
MISTRETTA, CA .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :116-121
[33]   Navigator-echo-base real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography [J].
Wang, Y ;
Rossman, PJ ;
Grimm, RC ;
Riederer, SJ ;
Ehman, RL .
RADIOLOGY, 1996, 198 (01) :55-60
[34]   3D CORONARY MR-ANGIOGRAPHY IN MULTIPLE BREATH-HOLDS USING A RESPIRATORY FEEDBACK MONITOR [J].
WANG, Y ;
GRIMM, RC ;
ROSSMAN, PJ ;
DEBBINS, JP ;
RIEDERER, SJ ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :11-16
[35]   RESPIRATORY MOTION OF THE HEART - KINEMATICS AND THE IMPLICATIONS FOR THE SPATIAL-RESOLUTION IN CORONARY IMAGING [J].
WANG, Y ;
RIEDERER, SJ ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :713-719
[36]   SINGLE BREATH-HOLD VOLUMETRIC IMAGING OF THE HEART USING MAGNETIZATION-PREPARED 3-DIMENSIONAL SEGMENTED ECHO [J].
WIELOPOLSKI, PA ;
MANNING, WJ ;
EDELMAN, RR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :403-409
[37]   Structure adaptive anisotropic image filtering [J].
Yang, GZ ;
Burger, P ;
Firmin, DN ;
Underwood, SR .
IMAGE AND VISION COMPUTING, 1996, 14 (02) :135-145
[38]  
YANG GZ, 1997, P ISMRM 5 ANN M VANC, P1885
[39]  
Zhou X., 1996, PROC 4 ANN M ISMRM N, P386