Arrays of microelectrodes with high charge transfer capacity have been fabricated and characterized. Nano-porous titanium nitride thin films were deposited onto a 3-dimensional micro-fabricated structure etched into a biocompatible polyimide insulation layer. The polymer layer was micro-patterned by electron beam lithography and etched in an oxygen-plasma. Measurements at 1 kHz/100 mV in electrolytic solution (PBS) show a significant reduction of impedance by a factor of 0.3 to 0.2 and are in good agreement with the surface gain expected from the 3-dimensional micro-pattern. The influence of the series resistance of the buffer solution on the electrode impedance is also examined by impedance spectroscopy and finite element simulation. This kind of microelectrodes may finally be used for stimulation and recording of cells and tissue.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 13 条
[1]   A novel organotypic long-term culture of the rat hippocampus on substrate-integrated multielectrode arrays [J].
Egert, U ;
Schlosshauer, B ;
Fennrich, S ;
Nisch, W ;
Fejtl, M ;
Knott, T ;
Muller, T ;
Hammerle, H .
BRAIN RESEARCH PROTOCOLS, 1998, 2 (04) :229-242
[2]  
HABERLAND HD, 1984, MEDIZINTECHNIK, V24, P103
[3]   EXTRACELLULAR RECORDING IN NEURONAL NETWORKS WITH SUBSTRATE INTEGRATED MICROELECTRODE ARRAYS [J].
HAMMERLE, H ;
EGERT, U ;
MOHR, A ;
NISCH, W .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (9-10) :691-696
[4]   Micromachined electrodes for high density neural stimulation systems [J].
Hung, A ;
Zhou, D ;
Greenberg, R ;
Judy, JW .
FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, :56-59
[5]   Action potential propagation failures in long-term recordings from embryonic stem cell-derived cardiomyocytes in tissue culture [J].
Igelmund, P ;
Fleischmann, BK ;
Fischer, IR ;
Soest, J ;
Gryshchenko, O ;
Böhm-Pinger, MM ;
Sauer, H ;
Liu, QH ;
Hescheler, J .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1999, 437 (05) :669-679
[6]  
JANDERS M, 1996, C P 18 ANN INT C IEE
[7]  
MINDT W, 1975, ADV PACEMAKER TECHNO, P297
[8]  
Navarro X, 1998, J PERIPHER NERV SYST, V3, P91
[9]   A THIN-FILM MICROELECTRODE ARRAY FOR MONITORING EXTRACELLULAR NEURONAL-ACTIVITY IN-VITRO [J].
NISCH, W ;
BOCK, J ;
EGERT, U ;
HAMMERLE, H ;
MOHR, A .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (9-10) :737-741
[10]  
Pine J, 1997, P IEEE EMBS, V18, P2133, DOI 10.1109/IEMBS.1996.646466