Direct characterization of intact polypeptides by matrix-assisted laser desorption electrospray ionization quadrupole Fourier transform ion cyclotron resonance mass spectrometry

被引:46
作者
Sampson, Jason S. [1 ]
Hawkridge, Adam M. [1 ]
Muddiman, David C. [1 ]
机构
[1] N Carolina State Univ, Dept Chem, WM Keck FT ICR Mass Spectrometry Lab, Raleigh, NC 27695 USA
关键词
D O I
10.1002/rcm.2947
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the characterization of a recently introduced hybrid ionization source, matrix-assisted laser desorption electrospray ionization (MALDESI), coupled to a quadrupole Fourier transform ion cyclotron resonance mass spectrometry (QFT-ICR-MS) system. We first demonstrate the ability of MALDESI-QFT-ICR MS to directly analyze and provide high mass measurement accuracy (similar to 1 part-per-million) of a polypeptide using internal calibration. Second, we show the potential of MALDESI-QFT-ICR MS for the top-down characterization of multiply charged polypeptide cations. Finally, we demonstrate sub-femtomole detection limits in MALDESI-QFT-ICR MS using a combination of naturally occurring peptides and their respective stable isotope labeled forms. The results presented herein demonstrate the feasibility of several potential applications for MALDESI-QFT-CR MS for the direct analysis of intact biological molecules. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:1150 / 1154
页数:5
相关论文
共 28 条
[11]   Top down versus bottom up protein characterization by tandem high-resolution mass spectrometry [J].
Kelleher, NL ;
Lin, HY ;
Valaskovic, GA ;
Aaserud, DJ ;
Fridriksson, EK ;
McLafferty, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (04) :806-812
[12]   Generating multiply charged protein ions via two-step electrospray ionization mass spectrometry [J].
Lee, CC ;
Chang, DY ;
Jeng, J ;
Shiea, J .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (01) :115-117
[13]   PRIMARY SEQUENCE INFORMATION FROM INTACT PROTEINS BY ELECTROSPRAY IONIZATION TANDEM MASS-SPECTROMETRY [J].
LOO, JA ;
EDMONDS, CG ;
SMITH, RD .
SCIENCE, 1990, 248 (4952) :201-204
[14]  
Marshall AG, 1996, RAPID COMMUN MASS SP, V10, P1819, DOI 10.1002/(SICI)1097-0231(199611)10:14<1819::AID-RCM686>3.0.CO
[15]  
2-Z
[16]   Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments [J].
McEwen, CN ;
McKay, RG ;
Larsen, BS .
ANALYTICAL CHEMISTRY, 2005, 77 (23) :7826-7831
[17]   Statistical evaluation of internal and external mass calibration laws utilized in Fourier transform ion cyclotron resonance mass spectrometry [J].
Muddiman, DC ;
Oberg, AL .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2406-2414
[18]   Dual electrospray ionization source for confident generation of accurate mass tags using liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry [J].
Nepomuceno, AI ;
Muddiman, DC ;
Bergen, HR ;
Craighead, JR ;
Burke, MJ ;
Caskey, PE ;
Allan, JA .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3411-3418
[19]   'Top down' protein characterization via tandem mass spectrometry [J].
Reid, GE ;
McLuckey, SA .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (07) :663-675
[20]   Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry [J].
Sampson, Jason S. ;
Hawkridge, Adam M. ;
Muddiman, David C. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (12) :1712-1716