Using the electrochemistry of the electrospray ion source

被引:171
作者
Van Berkel, Gary J. [1 ]
Kertesz, Vilmos [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Organ & Biol MS Grp, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac071944a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Armed with knowledge of the fundamental electrochemical aspects of the ion source, users of ESI MS are positioned to understand when and how this electrochemistry might be analytically important in terms of their particular MS studies or applications. It is our hope that this information will be exploited to bring to light new possibilities for ESI MS. The use of alternative electrode configurations and emitters with current and/or potential control, which allows one to control the electrochemical reactions, and the utilization of electrochemically initiated homogeneous chemistries are particular areas for growth. Understanding and using the electrochemical processes in the expanding area of nanoES systems will be another important area of research (47, 48). Improved comprehension of the electrochemical aspects of the ES process will continue to enlarge the utility of ESI MS for analytical chemists.
引用
收藏
页码:5510 / 5520
页数:11
相关论文
共 51 条
[1]   MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL [J].
BLADES, AT ;
IKONOMOU, MG ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2109-2114
[2]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[3]   MICROTUBE FLOWING COULOMETRY [J].
CHEN, LF ;
COLYER, CL ;
KAMAU, MG ;
MYLAND, JC ;
OLDHAM, KB ;
SYMONS, PG .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1994, 72 (03) :836-849
[4]  
Cole R.B., 1997, Electrospray Ionization Mass Spectrometry
[5]  
Cole RB, 2000, J MASS SPECTROM, V35, P763, DOI 10.1002/1096-9888(200007)35:7<763::AID-JMS16>3.0.CO
[6]  
2-#
[7]   On-line counting of cysteine residues in peptides during electrospray ionization by electrogenerated tags and their application to protein identification [J].
Dayon, L ;
Roussel, C ;
Prudent, M ;
Lion, N ;
Girault, HH .
ELECTROPHORESIS, 2005, 26 (01) :238-247
[8]  
de la Mora JF, 2000, J MASS SPECTROM, V35, P939
[9]   On-line electrochemistry - MS and related techniques [J].
Diehl, G ;
Karst, U .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :390-398
[10]   ELECTROSPRAY MASS-SPECTROMETRY OF ELECTROCHEMICALLY IONIZED MOLECULES - APPLICATION TO THE STUDY OF FULLERENES [J].
DUPONT, A ;
GISSELBRECHT, JP ;
LEIZE, E ;
WAGNER, L ;
VANDORSSELAER, A .
TETRAHEDRON LETTERS, 1994, 35 (33) :6083-6086