A comparative dosimetric study on tangential photon beams, intensity-modulated radiation therapy (IMRT) and modulated electron radiotherapy (MERT) for breast cancer treatment

被引:92
作者
Ma, CM
Ding, M
Li, JS
Lee, MC
Pawlicki, T
Deng, J
机构
[1] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
[2] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[3] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
关键词
D O I
10.1088/0031-9155/48/7/308
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, energy- and intensity-modulated electron radiotherapy (MERT) has garnered a growing interest for the treatment of superficial targets. In this work, we carried out a comparative dosimetry study to evaluate MERT, photon beam intensity-modulated radiation therapy (IMRT) and conventional tangential photon beams for the treatment of breast cancer. A Monte Carlo based treatment planning system has been investigated, which consists of a set of software tools to perform accurate dose calculation, treatment optimization, leaf sequencing and plan analysis. We have compared breast treatment plans generated using this home-grown treatment optimization and dose calculation software for these treatment techniques. The MERT plans were planned with up to two gantry angles and four nominal energies (6, 9, 12 and 16 MeV). The tangential photon treatment plans were planned with 6 MV wedged photon beams. The IMRT plans were planned using both multiple-gantry 6 MV photon beams or two 6 MV tangential beams. Our results show that tangential IMRT can reduce the dose to the lung, heart and contralateral breast compared to conventional tangential wedged beams (up to 50% reduction in high dose volume or 5 Gy in the maximum dose). MERT can reduce the maximum dose to the lung by up to 20 Gy and to the heart by up to 35 Gy compared to conventional tangential wedged beams. Multiple beam angle IMRT can significantly reduce the maximum dose to the lung and heart (up to 20 Gy) but it induces low and medium doses to a large volume of normal tissues including lung, heart and contralateral breast. It is concluded that MERT has superior capabilities to achieve dose conformity both laterally and in the depth direction, which will be well suited for treating superficial targets such as breast cancer.
引用
收藏
页码:909 / 924
页数:16
相关论文
共 57 条
[1]   Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation [J].
Asell, M ;
Hyodynmaa, S ;
Gustafsson, A ;
Brahme, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2083-2100
[2]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[3]  
Boyd R, 2002, MED PHYS, V29, P1285
[4]   Modulated beam conformal therapy for head and neck tumors [J].
Boyer, AL ;
Geis, P ;
Grant, W ;
Carol, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :227-236
[5]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[6]   The use of compensators to optimise the three dimensional dose distribution in radiotherapy of the intact breast [J].
Carruthers, LJ ;
Redpath, AT ;
Kunkler, IH .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :291-300
[7]   A comparison of different intensity modulation treatment techniques for tangential breast irradiation [J].
Chang, SX ;
Deschesne, KM ;
Cullip, TJ ;
Parker, SA ;
Earnhart, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05) :1305-1314
[8]   A simplified intensity modulated radiation therapy technique for the breast [J].
Chui, CS ;
Hong, L ;
Hunt, M ;
McCormick, B .
MEDICAL PHYSICS, 2002, 29 (04) :522-529
[9]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[10]   A Monte Carlo investigation of fluence profiles collimated by an electron specific MLC during beam delivery for modulated electron radiation therapy [J].
Deng, J ;
Lee, MC ;
Ma, CM .
MEDICAL PHYSICS, 2002, 29 (11) :2472-2483