Angio-CT: heart and coronary arteries

被引:13
作者
Kopp, AF [1 ]
机构
[1] Univ Tubingen Hosp, Tubingen, Germany
关键词
coronary arteriosclerosis; CT angiography; plaque morphology; contrast media;
D O I
10.1016/S0720-048X(02)00360-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite a multitude of different medical and interventional strategies to treat coronary artery disease (CAD), the natural course of CAD is a relentless progression. The current gold-standard to assess the degree of stenosis is coronary angiography. In Germany alone, the total number of angiographic procedures rose by 45% from 1995 to 2000, while the fraction of interventional procedures remained almost constantly low at about 30% [Z. Kardiol. 90 (2001) 665]. Although coronary angiography has become a safe procedure with only a small risk associated, the inconvenience for the patient as well as the economic burden have fueled the quest to find an alternative, non-invasive method to visualize and assess coronary arteries. The following article will explore the application of computed tomography (CT) coronary angiography for detection of stenoses, and the issue of imaging of non-calcified and unstable plaques with MDCT. (C) 2002 Published by Elsevier Science Ireland Ltd.
引用
收藏
页码:S32 / S36
页数:5
相关论文
共 21 条
[1]   Current development of cardiac imaging with multidetector-row CT [J].
Becker, CR ;
Ohnesorge, BM ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) :97-103
[2]   New coronary imaging techniques: what to expect? [J].
de Feyter, PJ ;
Nieman, K .
HEART, 2002, 87 (03) :195-197
[3]   ANGINA-PECTORIS AND DISEASE PROGRESSION [J].
FALK, E ;
FUSTER, V .
CIRCULATION, 1995, 92 (08) :2033-2035
[4]  
FLOHR T, 2002, EUR RADIOL, V12, pS217
[5]   The optimal time point in RR interval for data reconstructioin to visualize coronary arteries by multi slice computed tomography. [J].
Georg, C ;
Kopp, A ;
Schröder, S ;
Küttner, A ;
Ohnesorge, B ;
Martensen, J ;
Clausen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (06) :536-541
[6]   Current results and new developments of coronary angiography with use of contrast-enhanced computed tomography of the heart [J].
Gerber, TC ;
Kuzo, RS ;
Karstaedt, N ;
Lane, GE ;
Morin, RL ;
Sheedy, PF ;
Safford, RE ;
Blackshear, JL ;
Pietan, JH .
MAYO CLINIC PROCEEDINGS, 2002, 77 (01) :55-71
[7]  
HABERL R, 2001, J CLIN BASIC CARDIOL, V4, P241
[8]   Visualization techniques for multislice CT datasets of coronary arteries: Correlation of axial, multiplanar, three-dimensional, and virtual endoscopic imaging with coronary angiography [J].
Herzog, C ;
Ay, M ;
Engelmann, K ;
Abolmaali, N ;
Dogani, S ;
Diebold, T ;
Vogl, TJ .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :341-349
[9]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[10]   Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses [J].
Knez, A ;
Becker, CR ;
Leber, A ;
Ohnesorge, B ;
Becker, A ;
White, C ;
Haberl, R ;
Reiser, MF ;
Steinbeck, G .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1191-+