Development of a liquid chromatography-mass spectrometry method for the high-accuracy determination of creatinine in serum

被引:66
作者
Stokes, P [1 ]
O'Connor, G [1 ]
机构
[1] LGC Ltd, Specialised Tech, Teddington TW11 0LY, Middx, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 794卷 / 01期
关键词
creatinine;
D O I
10.1016/S1570-0232(03)00424-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An LC-MS method for the high-accuracy determination of creatinine in serum has been developed and used to provide results for an international measurement evaluation programme (IMEP) and the Comite Consultatif pour la Quantite de Matiere (CCQM) international inter-laboratory studies. An assessment of different sample preparation methods, including ion-exchange chromatography, solid-phase extraction, plasma ultrafiltration and ethanol protein precipitation, revealed that no bias or reduced precision was associated with the quicker less extensive clean-up methods, when using liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) for quantitation. A number of different calibration regimes were also investigated. External calibration was shown to provide adequate calibration for most routine analysis with a relative associated expanded uncertainty (k=2) of 6% at the 95% confidence level. The use of a non-isotopically labelled internal standard was shown to improve the relative expanded uncertainty (k=2) to 4%. However, the difference in retention time between the internal standard and the creatinine was such that a matrix interferent produced an observed bias of over 16%. The use of an isotopically labelled internal standard was shown to reduce any bias to less than 0.2% with an expanded uncertainty (k=2) of less than 0.3%. The developed method was then used, in a blind trial organised jointly by IMEP and CCQM. to determine the amount of creatinine in human serum. The method performed well against the established reference method of ion-exchange chromatography followed by derivatisation gas chromatography (GC)-IDMS. The observed difference between the values determined by LC-IDMS and the key comparison reference value (average of all the submitted results) was less than 0.3%. The biggest advantage of the described method is in the speed of analysis. With a chromatographic run time of less than 10 min and sample preparation consisting of a simple protein precipitation, without the need for a derivatisation stage, the analysis is vastly simpler then the conventional GC-IDMS reference method. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 14 条
[1]  
HENKEL E, 1980, ANAL CHEM, V301, P175
[2]   REDUCTION OF SYSTEMATIC-ERRORS IN QUANTITATIVE-ANALYSIS BY ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) - AN ITERATIVE METHOD [J].
HENRION, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12) :657-658
[3]  
International Organization for Standardization, 1993, GUID EXPR UNC MEAS
[4]   Simultaneous and rapid analysis of cyclosporin A and creatinine in finger prick blood samples using liquid chromatography tandem mass spectrometry and its application in C2 monitoring [J].
Keevil, BG ;
Tierney, DP ;
Cooper, DP ;
Morris, MR ;
Machaal, A ;
Yonan, N .
THERAPEUTIC DRUG MONITORING, 2002, 24 (06) :757-767
[5]  
*LGC, 2000, QUANT UNC AN MEAS EU
[6]   Definitive method certification of clinical analytes in lyophilized human serum: NIST standard reference material (SRM) 909b [J].
Phinney, CS ;
Murphy, KE ;
Welch, MJ ;
Ellerbe, PM ;
Long, SE ;
Pratt, KW ;
Schiller, SB ;
Sniegoski, LT ;
Rearick, MS ;
Vetter, TW ;
Vocke, RD .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (02) :71-80
[7]  
Sargent M., 2002, Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry
[8]  
SIEKMANN L, 1985, J CLIN CHEM CLIN BIO, V23, P137
[9]   DETERMINATION OF SERUM CREATININE BY ISOTOPE-DILUTION MASS-SPECTROMETRY WITH LIQUID-CHROMATOGRAPHIC SEPARATION [J].
TAKATSU, A ;
NISHI, S .
ANALYTICAL SCIENCES, 1990, 6 (03) :347-350
[10]   DETERMINATION OF SERUM CREATININE BY ISOTOPE-DILUTION METHOD USING DISCHARGE-ASSISTED THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
TAKATSU, A ;
NISHI, S .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (11) :643-646