Sensitive reagentless electrochemical immunosensor based on an ormosil sol-gel membrane for human chorionic gonadotrophin

被引:39
作者
Tan, Fang
Yan, Feng
Ju, Huangxian [1 ]
机构
[1] Nanjing Univ, Dept Chem, Educ Minist China, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210093, Peoples R China
基金
中国国家自然科学基金;
关键词
immunosensors; ormosil; sol-gel; enzyme labeled antibody; human chorionic gonadotrophin;
D O I
10.1016/j.bios.2006.12.010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new organically modified silicate (ormosil) material was synthesized as a matrix to encapsulate enzyme labeled antibody for preparation of immunosensors. The ormosil matrix was prepared by hydrolyzing tetraethyoxysi lane and (3-aminopropyl)triethoxysitane in weak alkali solution. It possessed three-dimensional ordered nanoporous structure with high electrical conductivity and good mechanical stability. Its hydrophilicity provided a microenvironment for retaining the biological activity of the immobilized protein. Particularly, using horseradish peroxidase-labeled human chorionic gonadotrophin antibody (HRP-anti-hCG) as a model, the immobilized HRP showed direct electron transfer at about -35 mV with a rate constant of 15.8 +/- 3.8 s(-1). By a simple one-step immunoreaction between human serum chorionic gonadotrophin (hCG) in sample solution and the immobilized HRP-anti-hCG, the differential pulse voltarnmetric peak current of HRP decreased linearly with an increasing hCG concentration from 0.5 to 50 mIU/mI with a relatively low limit of detection of 0.3 mIU/mI at 3 sigma. Excellent analytical performance, fabrication reproducibility and operational stability of the proposed biosensor indicated its promising application in clinical diagnostics. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2945 / 2951
页数:7
相关论文
共 44 条
[21]  
Lei CH, 1999, ELECTROANAL, V11, P274, DOI 10.1002/(SICI)1521-4109(199904)11:4<274::AID-ELAN274>3.0.CO
[22]  
2-G
[23]   Hydrogen peroxide sensor based on coimmobilized methylene green and horseradish peroxidase in the same montmorillonite-modified bovine serum albumin-glutaraldehyde matrix on a glassy carbon electrode surface [J].
Lei, CH ;
Deng, JQ .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3344-3349
[24]   Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide [J].
Li, J ;
Tan, SN ;
Ge, HL .
ANALYTICA CHIMICA ACTA, 1996, 335 (1-2) :137-145
[25]   Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin [J].
Lim, TK ;
Matsunaga, T .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :1063-1069
[26]   Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode [J].
Liu, SQ ;
Ju, HX .
ANALYTICAL BIOCHEMISTRY, 2002, 307 (01) :110-116
[27]  
LODE VP, 2003, ANAL CHEM, V75, P3193
[28]   Membrane electrodes can modulate the electrochemical response of redox proteins -: direct electrochemistry of cytochrome c [J].
Lojou, É ;
Bianco, P .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 485 (01) :71-80
[29]   Organically modified silica sol-mediated capillary electrophoresis [J].
Neiman, B ;
Grushka, E ;
Gun, J ;
Lev, O .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3484-3491
[30]   Better chemistry through ceramics: The physical bases of the outstanding chemistry of ORMOSIL [J].
Pagliaro, M ;
Ciriminna, R ;
Man, MWC ;
Campestrini, S .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (05) :1976-1988