Characterization of liver lesions by real-time contrast-enhanced ultrasonography

被引:145
作者
Celli, Natascia [1 ]
Gaiani, Stefano [1 ]
Piscaglia, Fabio [1 ]
Zironi, Gianni [1 ]
Camaggi, Valerla [1 ]
Leoni, Simona [1 ]
Righini, Roberto [1 ]
Bolondi, Luigi [1 ]
机构
[1] Univ Bologna, Dept Internal Med & Gastroenterol, Alma Mater Studiorum, Bologna, Italy
关键词
liver tumors (diagnosis); ultrasound contrast agent; ultrasound harmonic imaging;
D O I
10.1097/01.meg.0000250585.53608.3c
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective: The aim of this study was to identify the most common patterns of various common liver lesions at real-time contrast-enhanced ultrasonography with second-generation contrast agents and their role in the differentiation of malignant from benign lesions. Patients and methods: The enhancement pattern in the arterial phase and its modifications in subsequent portal and sinusoidal phases were separately evaluated in (i) 171 liver lesions detected at conventional ultrasonography in 125 noncirrhotic patients (87 metastases, six cholangiocellular carcinoma, 38 focal nodular hyperplasia, 30 hemangiomas, seven focal fatty sparing/changes, two hepatocellular adenomas and one hepatocellular carcinoma) and (ii) 75 lesions detected in 67 cirrhotic patients (66 hepatocellular carcinoma and nine dysplastic nodules). The final diagnosis was made by contrast-enhanced helical computed tomography and/or magnetic resonance imaging or by ultrasonography-guided biopsy when the diagnosis was equivocal at conventional imaging techniques (45 lesions). Results: In noncirrhotic patients, the hypoechoic pattern in portal and sinusoidal phase (rapid washout) or the markedly hypoechoic or anechoic pattern in sinusoidal phase (marked late washout) showed a sensitivity, specificity and accuracy of 96.8, 100 and 98.2% for the diagnosis of malignancy. In cirrhotic patients, early arterial enhancement showed a sensitivity of 93.9% for the diagnosis of malignancy, with a specificity as low as 55.5% given the presence of arterial enhancement in 5/9 nodules resulted dysplastic at histological analysis. Conclusion: Real-time contrast-enhanced ultrasonography provides sensitive and specific criteria for the differential diagnosis between benign and malignant liver lesions, and in most cases it may replace more expensive and invasive imaging techniques.
引用
收藏
页码:3 / 14
页数:12
相关论文
共 49 条
[1]
Characterization of unifocal liver lesions with pulse inversion harmonic imaging after Levovist injection: preliminary results [J].
Bertolotto, M ;
Dalla Palma, L ;
Quaia, E ;
Locatelli, M .
EUROPEAN RADIOLOGY, 2000, 10 (09) :1369-1376
[2]
Do different types of liver lesions differ in their uptake of the microbubble contrast agent SHU 508A in the late liver phase? Early experience [J].
Blomley, MJK ;
Sidhu, PS ;
Cosgrove, DO ;
Albrecht, T ;
Harvey, CJ ;
Heckemann, RA ;
Butler-Barnes, J ;
Eckersley, RJ ;
Basilico, R .
RADIOLOGY, 2001, 220 (03) :661-667
[3]
Focal nodular hyperplasia: CT findings with emphasis on multiphasic helical CT in 78 patients [J].
Brancatelli, G ;
Federle, MP ;
Grazioli, L ;
Blachar, A ;
Peterson, MS ;
Thaete, L .
RADIOLOGY, 2001, 219 (01) :61-68
[4]
Management of hepatoceullular carcinoma [J].
Bruix, J ;
Sherman, M .
HEPATOLOGY, 2005, 42 (05) :1208-1236
[5]
Clinical management of hepatocellular carcinoma.: Conclusions of the Barcelona-2000 EASL Conference [J].
Bruix, J ;
Sherman, M ;
Llovet, JM ;
Beaugrand, M ;
Lencioni, R ;
Burroughs, AK ;
Christensen, E ;
Pagliaro, L ;
Colombo, M ;
Rodés, J .
JOURNAL OF HEPATOLOGY, 2001, 35 (03) :421-430
[6]
Improved characterization of liver lesions with liver-phase uptake of liver-specific microbubbles: Prospective multicenter study [J].
Bryant, TH ;
Blomley, MJ ;
Albrecht, T ;
Sidhu, PS ;
Leen, ELS ;
Basilico, R ;
Pilcher, JM ;
Bushby, LH ;
Hoffmann, CW ;
Harvey, CJ ;
Lynch, M ;
MacQuarrie, J ;
Paul, D ;
Cosgrove, DO .
RADIOLOGY, 2004, 232 (03) :799-809
[7]
Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[8]
Infusion versus bolus of an ultrasound contrast agent - In vivo dose-response measurements of BR1 [J].
Correas, JM ;
Burns, PN ;
Lai, XM ;
Qi, XL .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :72-79
[9]
Cosgrove D. O., 2002, ELEKTROMEDICA, V70, P147
[10]
Focal hepatic masses: Enhancement patterns with SHU 508A and pulse-inversion US [J].
Dill-Macky, MJ ;
Burns, PN ;
Khalili, K ;
Wilson, SR .
RADIOLOGY, 2002, 222 (01) :95-102