Validation of volume measurements in esophageal pseudotumors using 3D endoluminal ultrasound

被引:10
作者
Liu, JB
Miller, LS
Chung, CY
Overton, DA
Sheera, M
Forsberg, F
Goldberg, BB
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Div Diagnost Ultrasound, Philadelphia, PA 19107 USA
[2] Temple Univ Hosp, Dept Med, Div Gastroenterol, Philadelphia, PA 19140 USA
关键词
three-dimensional; endoluminal ultrasound; esophageal tumor; volume measurement;
D O I
10.1016/S0301-5629(00)00205-2
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
The purpose of this study was to validate the accuracy and reliability of volume measurements using three-dimensional (3D) endoluminal ultrasound (ELUS) in canine pseudotumor esophageal specimens in vitro, Pseudotumors were created by injecting various volumes of US gel (0.1-1.0 ml) into canine esophageal specimens. A stepping-motor was used to pull either a 9, 12.5 or 20 MHz transducer through the lumen of the specimen at 1.5 mm/s. Images were downloaded to a LIFE computer system for 3D reconstruction. Volume measurements mere made by two investigators and compared to spiral CT images. Averaging across all measurements, the average magnitude of error was 8.7% in individual US determinations and 11.9% in CT measures. Volumes estimated from images spaced 0.5 and 1.0 mm apart, from images in the original and reconstructed planes, and from different scan frequencies, produced percentage errors that mere not statistically significantly different from each other on ELUS, 3D ELUS can be used accurately and reproducibly to measure tumor volumes with a low mean percent irt vitro, (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:735 / 741
页数:7
相关论文
共 19 条
[1]
Three-dimensional endoluminal ultrasonography of the ureter [J].
Bagley, DH ;
Liu, JB .
JOURNAL OF ENDOUROLOGY, 1998, 12 (05) :411-416
[2]
3-DIMENSIONAL VOLUMETRIC ULTRASOUND IMAGING OF ARTERIAL PATHOLOGY FROM 2-DIMENSIONAL INTRAVASCULAR ULTRASOUND - AN IN-VITRO STUDY [J].
CHANDRASEKARAN, K ;
SEHGAL, CM ;
HSU, TL ;
YOUNG, NA ;
DADAMO, AJ ;
ROBB, RA ;
PANDIAN, NG .
ANGIOLOGY, 1994, 45 (04) :253-264
[3]
Three-dimensional ultrasound assessment of fetal liver volume in normal pregnancy: A comparison of reproducibility with two-dimensional ultrasound and a search for a volume constant [J].
Chang, FM ;
Hsu, KF ;
Ko, HC ;
Yao, BL ;
Chang, CH ;
Yu, CH ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) :381-389
[4]
Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions [J].
Evans, JL ;
Ng, KH ;
Wiet, SG ;
Vonesh, MJ ;
Burns, WB ;
Radvany, MG ;
Kane, BJ ;
Davidson, CJ ;
Roth, SI ;
Kramer, BL ;
Meyers, SN ;
McPherson, DD .
CIRCULATION, 1996, 93 (03) :567-576
[5]
3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[6]
IN-VITRO EVALUATION OF 3-DIMENSIONAL ULTRASONOGRAPHY IN VOLUME ESTIMATION OF ABDOMINAL ORGANS [J].
GILJA, OH ;
THUNE, N ;
MATRE, K ;
HAUSKEN, T ;
ODEGAARD, S ;
BERSTAD, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (02) :157-165
[7]
ULTRASONIC 3-DIMENSIONAL RECONSTRUCTION - IN-VITRO AND IN-VIVO VOLUME AND AREA MEASUREMENT [J].
HODGES, TC ;
DETMER, PR ;
BURNS, DH ;
BEACH, KW ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (08) :719-729
[8]
A study of the quantitative and qualitative impact of catheter shaft angulation in a mechanical intravascular ultrasound system [J].
Kearney, PP ;
Ramo, MP ;
Spencer, T ;
Shaw, TRD ;
Starkey, IR ;
McDicken, N ;
Sutherland, GR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :87-93
[9]
Feasibility of three-dimensional intravascular ultrasonography: Preliminary clinical studies [J].
Liu, JB ;
Bonn, J ;
Needleman, L ;
Chiou, HJ ;
Gardiner, GA ;
Goldberg, BB .
JOURNAL OF ULTRASOUND IN MEDICINE, 1999, 18 (07) :489-495
[10]
TRANSNASAL US OF THE ESOPHAGUS - PRELIMINARY MORPHOLOGICAL AND FUNCTION STUDIES [J].
LIU, JB ;
MILLER, LS ;
GOLDBERG, BB ;
FELD, RI ;
ALEXANDER, AA ;
NEEDLEMAN, L ;
CASTELL, DO ;
KLENN, PJ ;
MILLWARD, CL .
RADIOLOGY, 1992, 184 (03) :721-727