Multislice CT in cardiac and coronary angiography

被引:32
作者
Kopp, AF
Küttner, A
Trabold, T
Heuschmid, M
Schröder, S
Claussen, CD
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Internal Med, Div Cardiol, Tubingen, Germany
关键词
D O I
10.1259/bjr/30634988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the last 2 years, mechanical multidetector-row CT (MDCT) systems with simultaneous acquisition of four slices and a half second scanner rotation time have become widely available. Data acquisition with these scanners allows for considerably faster coverage of the heart volume compared with single slice scanning. This increased scan speed can be used for retrospective gating together with I mm collimated slice widths and allows coverage of the entire cardiac volume in one breath-hold. First results from studies in correlation with intracoronary ultrasound suggest that MDCT technology not only offers the possibility to visualize intracoronary stenoses non-invasively, but also to differentiate plaque morphology. This is especially the case with the next generation of 16-row MDCT systems. An increased number of simultaneously acquired slices and submillimetre collimation for cardiac applications allows true isotropic scanning with high temporal resolution. Contrast-enhanced MDCT is a promising non-invasive technique for the detection, visualization and characterization of stenotic artery disease. It could act as a gatekeeper prior to cardiac catherization and finally replace conventional diagnostic modalities.
引用
收藏
页码:S87 / S97
页数:11
相关论文
共 53 条
[41]  
Ohnesorge BM, 2000, RADIOLOGY, V217, P487
[42]  
Ohnesorge BM, 2000, CIRCULATION, V102, P398
[43]   Intravenous coronary angiography by electron beam computed tomography - A clinical evaluation [J].
Rensing, BJ ;
Bongaerts, A ;
van Geuns, RJ ;
van Ooijen, P ;
Oudkerk, M ;
de Feyter, PJ .
CIRCULATION, 1998, 98 (23) :2509-2512
[44]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666
[45]  
Sablayrolles Jean Louis, 2001, Rays (Rome), V26, P3
[46]  
Schoepf UJ, 2001, EUR RADIOL, V11, P1975
[47]   Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography [J].
Schroeder, S ;
Kopp, AF ;
Baumbach, A ;
Meisner, C ;
Kuettner, A ;
Georg, C ;
Ohnesorge, B ;
Herdeg, C ;
Claussen, CD ;
Karsch, KR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1430-1435
[48]   Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography - Experience in 94 patients [J].
Schroeder, S ;
Kopp, AF ;
Kuettner, A ;
Burgstahler, C ;
Herdeg, C ;
Heuschmid, M ;
Baumbach, A ;
Claussen, CD ;
Karsch, KR ;
Seipel, L .
CLINICAL IMAGING, 2002, 26 (02) :106-111
[49]   Accuracy of density measurements within plaques located in artificial coronary arteries by X-ray multislice CT: Results of a phantom study [J].
Schroeder, S ;
Flohr, T ;
Kopp, AF ;
Meisner, C ;
Kuettner, A ;
Herdeg, C ;
Baumbach, A ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :900-906
[50]   Evaluating coronary artery disease - Where does EBCT fit in? [J].
Sheppard, R ;
Eisenberg, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) :335-336