Microfluidic system with electrochemical and optical detection

被引:34
作者
Grabowska, Ilona [1 ]
Sajnoga, Michal [1 ]
Juchniewicz, Marcin [1 ]
Chudy, Michal [1 ]
Dybko, Artur [1 ]
Brzozka, Zbigniew [1 ]
机构
[1] Warsaw Univ Technol, Dept Analyt Chem, PL-00664 Warsaw, Poland
关键词
optical detection; electrochemical detection; creatinine determination; urea determination; PDMS;
D O I
10.1016/j.mee.2007.01.248
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes the construction of a polymer miniaturized system which allows carrying out urea and creatinine determination with using two various and independent methods: electrochemical as well as spectrophotometric. The application of dual determination of the bioanalyte makes obtained results more reliable. Additionally, it creates opportunities for monitoring urea and creatinine concentration during hemodialisis course. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1741 / 1743
页数:3
相关论文
共 9 条
[1]   Lab-on-a-chip systems for biomedical and environmental monitoring [J].
Gardeniers, JGE ;
van den Berg, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (07) :1700-1703
[2]   Architecture and method of fabrication PDMS system for uric acid determination [J].
Grabowska, I. ;
Stadnik, D. ;
Chudy, M. ;
Dybko, A. ;
Brzozka, Z. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (02) :445-451
[3]   Miniaturized total analysis systems for biological analysis [J].
Jakeway, SC ;
de Mello, AJ ;
Russell, EL .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :525-539
[4]  
JUCNIEWICZ M, MNE 06 MICR ENG SEPT, P443
[5]   Integrated microfluidic system for the simultaneous determination of ammonia, creatinine, and urea [J].
Suzuki, H ;
Matsugi, Y .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) :700-707
[6]   Micro total analysis systems. Recent developments [J].
Vilkner, T ;
Janasek, D ;
Manz, A .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3373-3385
[7]   Dual conductivity/amperometric detection system for microchip capillary electrophoresis [J].
Wang, J ;
Pumera, M .
ANALYTICAL CHEMISTRY, 2002, 74 (23) :5919-5923
[8]   Dual amperometric-potentiometric biosensor detection system for monitoring organophosphorus neurotoxins [J].
Wang, J ;
Krause, R ;
Block, K ;
Musameh, M ;
Mulchandani, A ;
Mulchandani, P ;
Chen, W ;
Schöning, MJ .
ANALYTICA CHIMICA ACTA, 2002, 469 (02) :197-203
[9]   Self-regulating heater for microluidic reactors [J].
Wyzkiewicz, I ;
Grabowska, I ;
Chudy, M ;
Brzozka, Z ;
Jakubowska, M ;
Wisniewski, T ;
Dybko, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) :893-896