Determination of aliphatic alcohols after on-line microwave-assisted derivatization by liquid chromatography-photodiode array detection

被引:21
作者
Chávez, G [1 ]
Bravo, B [1 ]
Piña, N [1 ]
Arias, M [1 ]
Vivas, E [1 ]
Ysambertt, F [1 ]
Márquez, N [1 ]
Cáceres, A [1 ]
机构
[1] Univ Zulia, Fac Ciencias, Dept Quim, Lab Petroquim & Surfactantes, Zulia 4005, Venezuela
关键词
continuous analysis; on-line systems; microwave assisted reaction; polyethoxylated alcohol surfactants;
D O I
10.1016/j.talanta.2004.05.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, high-performance liquid chromatography (HPLC) in conjunction with continuous derivatization for the determination of aliphatic and polyethoxylated alcohol is reported. Reaction of alcohol group with phenyl isocyanate or benzyl chloride reagents assisted with microwaves (MW) irradiation is carried out in an on-line system coupled to HPLC with photodiode array detection (PDA). Reactor was placed into a microwave oven at 450 W. The flow rate, reagent amounts, irradiation time, and chromatographic conditions were optimized. The continuous analysis using the system MW-HPLC-PDA provided high sensitivity, reduce the amount of reagents and analysis time. This proposed method can be used for the analysis of commercial alcohol polyethoxylated mixture. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1323 / 1328
页数:6
相关论文
共 18 条
[1]   ETHYLENE-OXIDE OLIGOMER DISTRIBUTION IN NON-IONIC SURFACTANTS VIA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) [J].
ALLEN, MC ;
LINDER, DE .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1981, 58 (10) :950-957
[2]  
Asmussen C, 1998, HRC-J HIGH RES CHROM, V21, P597
[3]   Microwave-induced organic reaction enhancement (MORE) chemistry. Part 13. Microwave-assisted rapid and simplified hydrogenation [J].
Banik, BK ;
Barakat, KJ ;
Wagle, DR ;
Manhas, MS ;
Bose, AK .
JOURNAL OF ORGANIC CHEMISTRY, 1999, 64 (16) :5746-5753
[4]   Derivatization LC/MS for the simultaneous determination of fatty alcohol and alcohol ethoxylate surfactants in water and wastewater samples [J].
Dunphy, JC ;
Pessler, DG ;
Morrall, SW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (06) :1223-1230
[5]   THE USE OF MICROWAVE-OVENS FOR RAPID ORGANIC-SYNTHESIS [J].
GEDYE, R ;
SMITH, F ;
WESTAWAY, K ;
ALI, H ;
BALDISERA, L ;
LABERGE, L ;
ROUSELL, J .
TETRAHEDRON LETTERS, 1986, 27 (03) :279-282
[6]   Determination of trace C1-C4 aliphatic alcohols in aqueous samples by 9-fluorenylmethyl chloroformate derivatization and reversed phase high performance liquid chromatography [J].
Huang, G ;
Deng, GH ;
Qiao, HC ;
Zhou, XL .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4245-4249
[7]   Investigation of chromatographic behaviour of ethoxylated alcohol surfactants in normal-phase and reversed-phase systems using high-performance liquid chromatography mass spectrometry [J].
Jandera, P ;
Holcapek, M ;
Theodoridis, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (02) :299-311
[8]   Functional group transformations of diols, cyclic ethers, and Lactones using aqueous hydrobromic acid and phase transfer catalyst under microwave irradiation [J].
Kad, GL ;
Kaur, I ;
Bhandari, M ;
Singh, J ;
Kaur, J .
ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2003, 7 (03) :339-340
[9]   Scaling up of dihydropyridine ester synthesis by using aqueous hydrotrope solutions in a continuous microwave reactor [J].
Khadilkar, BM ;
Madyar, VR .
ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2001, 5 (04) :452-455
[10]   Rapid and amenable Suzuki coupling reaction in water using microwave and conventional heating [J].
Leadbeater, NE ;
Marco, M .
JOURNAL OF ORGANIC CHEMISTRY, 2003, 68 (03) :888-892