Four-dimensional (4D) PET/CT imaging of the thorax

被引:272
作者
Nehmeh, SA
Erdi, YE
Pan, T
Pevsner, A
Rosenzweig, KE
Yorke, E
Mageras, GS
Schoder, H
Vernon, P
Squire, O
Mostafavi, H
Larson, SM
Humm, JL
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Gen Elect Med Syst, Waukesha, WI USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10021 USA
[4] Mem Sloan Kettering Canc Ctr, Dept Radiol, Nucl Med Serv, New York, NY 10021 USA
[5] Varian Med Syst, Palo Alto, CA USA
关键词
D O I
10.1118/1.1809778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four lung cancer patients were monitored by tracking external markers placed on the thorax. A 4D-CT acquisition was performed using a "step-and-shoot" technique, in which computed tomography (CT) projection data were acquired over a complete respiratory cycle at each couch position. The period of each CT acquisition segment was time stamped with an "x-ray ON" signal, which was recorded by the tracking system. 4D-CT data were then sorted into 10 groups, according to their corresponding phase of the breathing cycle. 4D-PET data were acquired in the Gated mode. where each breathing cycle was divided into ten 0.5 s bins. For both CT and PET acquisitions, patients received audio prompting to regularize breathing. The 4D-CT and 4D-PET data were then correlated according to respiratory phase. The effect of 4D acquisition on improving the co-registration of PET and CT images, reducing motion smearing, and consequently increase the quantitation of the SUV, were investigated. Also, quantitation of the tumor motions in PET, and CT were studied and compared. 4D-PET with matching phase 4D-CTAC showed an improved accuracy in PET-CT image co-registration of up to 41%, compared to measurements from 4D-PET with clinical-CTAC. Gating PET data in correlation with respiratory motion reduced motion-induced smearing, thereby decreasing the observed tumor volume, by as much as 43%. 4D-PET C lesions volumes showed a maximum deviation of 19% between clinical CT and phase- matched 4D-CT attenuation corrected PET images. In CT, 4D acquisition resulted in increasing the tumor volume in two patients by up to 79%, and decreasing it in the other two by up to 35%. Consequently, these corrections have yielded an increase in the measured SUV by up to 16% over the clinical measured SUV, and 36% over SUV's measured in 4D-PET with clinical-CT Attenuation Correction (CTAC) SUV's. Quantitation of the maximum tumor motion amplitude, using 4D-PET and 4D-CT, showed up to 30% discrepancy between the two modalities. We have shown that 4D PET/CT is clinically a feasible method, to correct for respiratory motion artifacts in PET/CT imaging of the thorax. 4D PET/CT acquisition can reduce smearing, improve the accuracy in PET-CT co-registration, and increase the measured SUV. This should result in an improved tumor assessment for patients with lung malignancies. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3179 / 3186
页数:8
相关论文
共 31 条
[1]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[2]   Can pet provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CY and the promise of PET [J].
Caldwell, CB ;
Mah, K ;
Skinner, M ;
Danjoux, CE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05) :1381-1393
[3]  
CHEN YX, 2004, KLUW S INF, V14, P1
[4]   Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT):: A feasibility study [J].
Ciernik, IF ;
Dizendorf, E ;
Baumert, BG ;
Reiner, B ;
Burger, C ;
Davis, JB ;
Lütolf, UM ;
Steinert, HC ;
Von Schulthess, GK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :853-863
[5]   The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy [J].
Dawson, LA ;
Brock, KK ;
Kazanjian, S ;
Fitch, D ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK ;
Balter, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1410-1421
[6]  
Erdi Y. E., 1997, CANCER, V80, P2502, DOI [10.1002/(SICI)1097-0142, DOI 10.1002/(SICI)1097-0142]
[7]  
Erdi YE, 2004, J NUCL MED, V45, P1287
[8]   Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Rosenzweig, KE ;
Wagman, R ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (02) :522-531
[9]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[10]   PET-CT image co-registration in the thorax: influence of respiration [J].
Goerres, GW ;
Kamel, E ;
Heidelberg, TNH ;
Schwitter, MR ;
Burger, C ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) :351-360