Phantoms for IMRT dose distribution measurement and treatment verification

被引:62
作者
Low, DA [1 ]
Gerber, RL [1 ]
Mutic, S [1 ]
Purdy, JA [1 ]
机构
[1] Edward Mallinckrodt Inst Radiol, Div Radiat Oncol, St Louis, MO 63110 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 40卷 / 05期
关键词
intensity-modulated radiation therapy; treatment verification; inverse planning; radiation therapy dosimetry phantom;
D O I
10.1016/S0360-3016(97)00910-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The verification of intensity-modulated radiation therapy (IMRT) patient treatment dose distributions is currently based on custom-built or modified dose measurement phantoms, The only commercially available IMRT treatment planning and delivery system (Peacock, NOMOS Corp.) is supplied with a film phantom that allows accurate spatial localization of the dose distribution using radiographic film, However, measurements using other dosimeters are necessary for the thorough verification of IMRT. Methods: We have developed a phantom to enable dose measurements using a cylindrical ionization chamber and the localization of prescription isodose curves using a matrix of thermoluminescent dosimetry (TLD) chips, The external phantom cross-section is identical to that of the commercial phantom, to allow direct comparisons of measurements, A supplementary phantom has been fabricated to verify the IMRT dose distributions for pelvis treatments. Results: To date, this phantom has been used for the verification of IMRT dose distributions for head and neck and prostate cancer treatments, Designs are also presented for a phantom insert to be used with polymerizing gels (e.g., BANG-2) to obtain volumetric dose distribution measurements, Conclusion: The phantoms have proven useful in the quantitative evaluation of IMRT treatments. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:1231 / 1235
页数:5
相关论文
共 18 条
[1]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[2]   A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering [J].
Burch, SE ;
Kearfott, KJ ;
Trueblood, JH ;
Sheils, WC ;
Yeo, JI ;
Wang, CKC .
MEDICAL PHYSICS, 1997, 24 (05) :775-783
[3]   The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation [J].
Carol, M ;
Grant, WH ;
Bleier, AR ;
Kania, AA ;
Targovnik, HS ;
Butler, EB ;
Woo, SW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (01) :183-187
[4]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[5]   Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels .1. Development of an optical scanner [J].
Gore, JC ;
Ranade, M ;
Maryanski, MJ ;
Schulz, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2695-2704
[6]  
GRANT W, 1996, P 1996 AAPM SUMM SCH
[7]   Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation [J].
Ling, CC ;
Burman, C ;
Chui, CS ;
Kutcher, GJ ;
Leibel, SA ;
LoSasso, T ;
Mohan, R ;
Bortfeld, T ;
Reinstein, L ;
Spirou, S ;
Wang, XH ;
Wu, QW ;
Zelefsky, M ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04) :721-730
[8]  
LOW DA, 1997, UNPUB RADIOTHER ONCO
[9]   Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels .2. Optical properties of the BANG polymer gel [J].
Maryanski, MJ ;
Zastavker, YZ ;
Gore, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2705-2717
[10]   MAGNETIC-RESONANCE-IMAGING OF RADIATION-DOSE DISTRIBUTIONS USING A POLYMER-GEL DOSIMETER [J].
MARYANSKI, MJ ;
SCHULZ, RJ ;
IBBOTT, GS ;
GATENBY, JC ;
XIE, J ;
HORTON, D ;
GORE, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09) :1437-1455