CT angiographic measurement of the carotid artery: Optimizing visualization by manipulating window and level settings and contrast material attenuation

被引:38
作者
Liu, Y
Hopper, KD
Mauger, DT
Addis, KA
机构
[1] Penn State Univ, Dept Radiol, Hershey, PA 17033 USA
[2] Penn State Univ, Dept Hlth Evaluat Sci, Hershey, PA 17033 USA
[3] Penn State Univ, Coll Med, Hershey, PA 17033 USA
[4] Hua Dong Hosp, Dept Radiol, Shanghai, Peoples R China
关键词
carotid arteries; angiography; CT; stenosis or obstruction; computed tomography (CT); maximum intensity projection; contrast media; experimental studies; phantoms;
D O I
10.1148/radiology.217.2.r00oc32494
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a broad range of window and level settings for various contrast material attenuation coefficients and degrees of vascular stenosis to obtain the most accurate computed tomographic (CT) angiographic measurements. MATERIALS AND METHODS: A total of 25,480 measurements were made transversely (perpendicular to the lumen) and by means of maximum intensity projection (M/P) in a phantom with stenoses of 0%-100%, contrast material with attenuation coefficients of 150-350 HU, and 14 window and 13 level settings. Edge definition was also evaluated. RESULTS: There was an inherent relationship between the contrast material attenuation coefficient and the optimal window and level settings in the measurement of stenoses at both transverse and MIP CT angiography. This relationship between the contrast material attenuation coefficient D and the optimal settings for window Wand level L was represented by the following simple equations: W/D = [-2 x (L/D)] + 1.3, where -0.2 < L/D < 0.5, and W/D = [3.3 x (UD)] - 1.3, where 0.5 < LID < 1.0. With a vascular contrast material attenuation coefficient of 250-350 HU, the best transverse and MIP display settings for the window and level were 96 and 150 HU, respectively. CONCLUSION: The use of optimized window and level settings at CT angiography reduces measurement variability.
引用
收藏
页码:494 / 500
页数:7
相关论文
共 21 条
[1]   Helical CT angiography compared with arteriography in the detection of renal artery stenosis [J].
Beregi, JP ;
Elkohen, M ;
Deklunder, G ;
Artaud, D ;
Coullet, JM ;
Wattinne, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :495-501
[2]   Assessment of renal artery stenosis with CT angiography: Usefulness of multiplanar reformation, quantitative stenosis measurements, and densitometric analysis of renal parenchymal enhancement as adjuncts to MIP film reading [J].
Berg, MH ;
Manninen, HI ;
Vanninen, RL ;
Vainio, PA ;
Soimakallio, S .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) :533-540
[3]   TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS [J].
BRINK, JA ;
LIM, JT ;
WANG, G ;
HEIKEN, JP ;
DEYOE, LA ;
VANNIER, MW .
RADIOLOGY, 1995, 194 (01) :157-163
[4]   Evaluation of contrast densities in the diagnosis of carotid stenosis by CT angiography [J].
Claves, JL ;
Wise, SW ;
Hopper, KD ;
Tully, D ;
TenHave, TR ;
Weaver, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (02) :569-573
[5]   CAROTID-ARTERY STENOSIS - A PROSPECTIVE COMPARISON OF CT ANGIOGRAPHY AND CONVENTIONAL ANGIOGRAPHY [J].
CUMMING, MJ ;
MORROW, IM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :517-523
[6]   A phantom study: Evaluation of renal artery stenosis using helical CT and 3D reconstructions [J].
Davros, WJ ;
Obuchowski, NA ;
Berman, PM ;
Zeman, RK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) :156-161
[7]   Blurring of vessels in spiral CT angiography: Effects of collimation width, pitch, viewing plane, and windowing in maximum intensity projection [J].
Diederichs, CG ;
Keating, DP ;
Glatting, G ;
Oestmann, JW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (06) :965-974
[8]   CT ANGIOGRAPHY - APPLICATION TO THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
EIKELBOOM, BC ;
MALI, WPTM .
RADIOLOGY, 1993, 189 (01) :211-219
[9]  
Dix JE, 1997, AM J NEURORADIOL, V18, P409
[10]   Renal artery stenosis: Detection and quantification with spiral CT angiography versus optimized digital subtraction angiography [J].
Kaatee, R ;
Beek, FJA ;
deLange, EE ;
vanLeeuwen, MS ;
Smits, HFM ;
vanderVen, PJG ;
Beutler, JJ ;
Mali, WPTM .
RADIOLOGY, 1997, 205 (01) :121-127