MRI-guided coronary catheterization and PTCA: A feasibility study on a dog model

被引:46
作者
Serfaty, JM
Yang, XM
Foo, TK
Kumar, A
Derbyshire, A
Atalar, E
机构
[1] Johns Hopkins Univ, Outpatient Ctr, Sch Med, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ Hosp, GE Med Syst, Appl Sci Lab, Baltimore, MD 21287 USA
关键词
coronary vessels; magnetic resonance imaging; arteries; transluminal angioplasty; catheter and catheterization; arteriosclerosis;
D O I
10.1002/mrm.10393
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this work was to demonstrate the feasibility of MRI-guided coronary artery catheterization and intervention in a dog model. Experiments were performed on 10 healthy dogs. A 9F introducer sheath was placed through a right carotid artery cutdown. A prototype 0.014-inch coronary MRI guidewire, a prototype 7 French MRI-guiding catheter, and two flexible surface coils were connected to a GE 1.5 T CV/i scanner for simultaneous visualization of the guidewire, guiding catheter, and chest anatomy. Images were displayed in real time on an in-room monitor. A nongated, single-slice fast gradient-echo sequence was used to obtain real-time images of the catheters and background anatomy during the intervention. Fifteen selective catheterizations were attempted in the coronary arteries, and all were successful. Selective injection of diluted gadolinium into the MRI-guiding catheter provided dynamic 2D projection coronary angiography in all cases, confirming successful catheterization. Percutaneous transluminal coronary angioplasty (PTCA) was attempted after two catheterizations, and all attempts were successful. Inflation of the balloon angioplasty catheter was performed successfully in the left anterior and circumflex arteries. Our results indicate that coronary artery catheterization and intracoronary balloon angioplasty are feasible with MRI guidance only. MRI guidance may be used as an alternative to X-ray guidance in coronary artery interventions in the future. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:258 / 263
页数:6
相关论文
共 39 条
[1]   Multiple field of view MR fluoroscopy [J].
Aksit, P ;
Derbyshire, JA ;
Serfaty, JM ;
Atalar, E .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :53-60
[2]   Catheter-tracking FOV MR fluoroscopy [J].
Atalar, E ;
Kraitchman, DL ;
Carkhuff, B ;
Lesho, J ;
Ocali, O ;
Solaiyappan, M ;
Guttman, MA ;
Charles, HK .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :865-872
[3]  
ATALAR E, 1999, P 7 ANN M ISMRM PHIL, P1060
[4]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[5]  
Bluemke DA, 1999, CRIT REV DIAGN IMAG, V40, P203
[6]  
Buecker A, 2000, J MAGN RESON IMAGING, V12, P616, DOI 10.1002/1522-2586(200010)12:4<616::AID-JMRI15>3.0.CO
[7]  
2-F
[8]  
CARR J, 2000, P 8 ANN M ISMRM DENV, P72
[9]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[10]   Catheter visualization using locally induced, actively controlled field inhomogeneities [J].
Glowinski, A ;
Adam, G ;
Bucker, A ;
Neuerburg, J ;
vanVaals, JJ ;
Gunther, RW .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :253-258