Monolithic chiral stationary phases for liquid-phase enantioseparation techniques

被引:61
作者
Chankvetadze, Bezhan [1 ]
机构
[1] Tbilisi State Univ, Sch Exact & Nat Sci, Dept Phys & Analyt Chem, GE-0179 Tbilisi, Georgia
基金
美国国家科学基金会;
关键词
Chromatography; Electrochromatography; Monolithic chiral stationary phases; Separation of enantiomers; EXCHANGE CAPILLARY ELECTROCHROMATOGRAPHY; SILICA COLUMNS; CELLULOSE TRIS(3,5-DIMETHYLPHENYLCARBAMATE); CHROMATOGRAPHIC ENANTIOSEPARATIONS; ENANTIOMER SEPARATION; AMINO-ACIDS; QUINIDINE FUNCTIONALITY; CONTINUOUS BEDS; PERFORMANCE; LIGAND;
D O I
10.1002/jssc.200900805
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
This short overview summarizes the development in the field of enantioselective monolithic chromatographic media and their application for pressure-driven and electrokinetic separations The major emphasis is put on the currently existing problems and the author's vision for their solution is provided Due to the author's personal experience silica-based monoliths are discussed in mote detail although the key developments in the field of organic monolithic materials for separation of enantiomers ate also discussed
引用
收藏
页码:305 / 314
页数:10
相关论文
共 67 条
[1]
FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]
Enantioselective catalysis and analysis on a chip [J].
Belder, D ;
Ludwig, M ;
Wang, LW ;
Reetz, MT .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (15) :2463-2466
[3]
Evaluation of a monolithic epoxy silica support for penicillin G acylase immobilization [J].
Calleri, E ;
Massolini, G ;
Lubda, D ;
Temporini, C ;
Loiodice, F ;
Caccialanza, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1031 (1-2) :93-100
[4]
Trends in the development of chiral drugs [J].
Caner, H ;
Groner, E ;
Levy, L ;
Agranat, I .
DRUG DISCOVERY TODAY, 2004, 9 (03) :105-110
[5]
High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic silica modified with amylose tris(3,5-dimethylphenylcarbamate) [J].
Chankvetadze, B ;
Yamamoto, C ;
Kamigaito, M ;
Tanaka, N ;
Nakanishi, K ;
Okamoto, Y .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1110 (1-2) :46-52
[6]
High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic [J].
Chankvetadze, B ;
Yamamoto, C ;
Tanaka, N ;
Nakanishi, K ;
Okamoto, Y .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) :905-911
[7]
Very fast enantioseparation in high-performance liquid chromatography using cellulose tris(3,5-dimethylphenylcarbamate) coated on monolithic silica support [J].
Chankvetadze, B ;
Yamamoto, C ;
Okamoto, Y .
CHEMISTRY LETTERS, 2003, 32 (09) :850-851
[8]
High-performance liquid chromatographic enantio separations on monolithic silica columns containing a covalently attached 3,5-dimethylphenylcarbamate derivative of cellulose [J].
Chankvetadze, B ;
Ikai, T ;
Yamamoto, C ;
Okamoto, Y .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1042 (1-2) :55-60
[9]
High-performance liquid chromatographic enantioseparations on capillary columns containing crosslinked polysaccharide phenylcarbamate derivatives attached to monolithic silica [J].
Chankvetadze, Bezhan ;
Kubota, Takateru ;
Ikai, Tomoyuki ;
Yamamoto, Chiyo ;
Kamigaito, Masami ;
Tanaka, Nobuo ;
Nakanishi, Kazuki ;
Okamoto, Yoshio .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (13) :1988-1995
[10]
Electrochromatographic enantioseparation using chiral ligand exchange monolithic sol-gel column [J].
Chen, Z ;
Nishiyama, T ;
Uchiyama, K ;
Hobo, T .
ANALYTICA CHIMICA ACTA, 2004, 501 (01) :17-23