Peripheral dose measurement with a MOSFET detector

被引:27
作者
Butson, MJ [1 ]
Cheung, T
Yu, PKN
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
关键词
MOSFET; dosimetry; accuracy; X-rays; high energy;
D O I
10.1016/j.apradiso.2004.09.001
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The accuracy of a MOSFET dosimetry system with respect to peripheral therapeutic doses from high-energy X-rays has been evaluated. The results have been compared with ionisation chamber measurements in the same peripheral regions of the beam. For 6 MV and 18 MV X-ray beams, the MOSFET system in the high-sensitivity mode produces reproducibility of dose measurement with relative standard deviations within 1% of the maximal dose in the beam, if the measurement is made upto 15 cm away from the beam edge. The results have shown that the MOSFET device can adequately measure peripheral doses, which would be beneficial for in vivo dose assessments in radiotherapy. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:631 / 634
页数:4
相关论文
共 11 条
[1]   Clinical dosimetry with MOSFET dosimeters to determine the dose along the field junction in a split beam technique [J].
Bloemen-van Gurp, E ;
du Bois, W ;
Visser, P ;
Bruinvis, I ;
Jalink, D ;
Hermans, J ;
Lambin, P .
RADIOTHERAPY AND ONCOLOGY, 2003, 67 (03) :351-357
[2]   A new radiotherapy surface dose detector: The MOSFET [J].
Butson, MJ ;
Rozenfeld, A ;
Mathur, JN ;
Carolan, M ;
Wong, TPY ;
Metcalfe, PE .
MEDICAL PHYSICS, 1996, 23 (05) :655-658
[3]   Radiochromic film for medical radiation dosimetry [J].
Butson, MJ ;
Yu, PKN ;
Cheung, T ;
Metcalfe, P .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5) :61-120
[4]   Investigation of the use of MOSFET for clinical IMRT dosimetric verification [J].
Chuang, CF ;
Verhey, LJ ;
Xia, P .
MEDICAL PHYSICS, 2002, 29 (06) :1109-1115
[5]  
HOLMESSIEDLE A, 2001, REMS INTERGRATING DO
[6]   Measurements in radiotherapy beams using on-line mosfet detectors [J].
Kron, T ;
Rosenfeld, A ;
Lerch, M ;
Bazley, S .
RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) :445-448
[7]   Measurement of radiotherapy x-ray skin dose on a chest wall phantom [J].
Quach, KY ;
Morales, J ;
Butson, MJ ;
Rosenfeld, AB ;
Metcalfe, PE .
MEDICAL PHYSICS, 2000, 27 (07) :1676-1680
[8]   Feasibility study of online high-spatial-resolution MOSFET dosimetry in static and pulsed X-ray radiation fields [J].
Rosenfeld, AB ;
Lerch, MLF ;
Kron, T ;
Brauer-Krisch, E ;
Bravin, A ;
Holmes-Siedle, A ;
Allen, BJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) :2061-2068
[9]  
Rosenfeld AB, 2002, RADIAT PROT DOSIM, V101, P393, DOI 10.1093/oxfordjournals.rpd.a006009
[10]   THE CONTRIBUTION OF BORDER TRAPS TO THE THRESHOLD VOLTAGE SHIFT IN PMOS DOSIMETRIC TRANSISTORS [J].
SAVIC, Z ;
RADJENOVIC, B ;
PEJOVIC, M ;
STOJADINOVIC, N .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1445-1454