Response function and analytical parameters of nitrite-selective optode membranes in absorbance and fluorescence mode

被引:20
作者
Demuth, C [1 ]
Spichiger, UE [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Pharm, Ctr Chem Sensors Biosensors & Bioanalyt Chem, CH-8005 Zurich, Switzerland
关键词
response function; nitrite; optode membranes;
D O I
10.1016/S0003-2670(97)00490-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four different nitrite-selective optode membranes were studied. Each membrane consisted of a nitrite-selective ligand and four different H+-selective chromoionophores dissolved in a plasticized poly(vinyl chloride) bulk medium. The membranes' analytical parameters differ with respect to optical spectra, dynamic range and detection limit. The unique features of each membrane are discussed and the versatility of the optical sensors based on the membranes is evaluated. The response functions of the optical sensors, derived from the changes in the absorbance and/or fluorescence of the membranes with varying nitrite concentration, are described by a theoretical model based on coextraction equilibria. The dynamic range of the sensors extended from 0.5 to 5000 mg l(-1) nitrite with a detection limit of 0.24 mg l(-1). The response time, tau(95), of the membranes placed in a continuous flow measuring cell was 1.2 min when changing from 0.5 mg l(-1) nitrite to 0.05 mg l(-1), and 3.6 min in the opposite direction. The selectivity coefficients determined by the separate solution method were: 10(-3.3) for nitrate, 10(-3.7) for chloride, 10(-3.0) for bromide, 10(-3.8) for sulphate, and 10(-5.0) for phosphate. Various applications of these optode membranes are discussed. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:259 / 268
页数:10
相关论文
共 35 条
[1]   Simultaneous spectrophotometric determination of nitrite nitrate by flow-injection analysis [J].
Ahmed, MJ ;
Stalikas, CD ;
TzouwaraKarayanni, SM ;
Karayannis, MI .
TALANTA, 1996, 43 (07) :1009-1018
[2]   NITRITE-SELECTIVE ELECTRODE BASED ON AN ELECTROPOLYMERIZED COBALT PHTHALOCYANINE [J].
ALLEN, JR ;
FLORIDO, A ;
YOUNG, SD ;
DAUNERT, S ;
BACHAS, LG .
ELECTROANALYSIS, 1995, 7 (08) :710-713
[3]  
[Anonymous], 1991, ACTIVITY COEFFICIENT, DOI DOI 10.1201/9781351069472
[4]  
[Anonymous], [No title captured]
[5]   POTENTIOMETRIC ANION SELECTIVITY OF POLYMER MEMBRANES DOPED WITH PALLADIUM ORGANOPHOSPHINE COMPLEX [J].
BADR, IHA ;
MEYERHOFF, ME ;
HASSAN, SSM .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2613-2618
[6]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[7]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[8]   DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES [J].
BAKKER, E ;
WILLER, M ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :265-271
[9]   Utilization of lipophilic ionic additives in liquid polymer film optodes for selective anion activity measurements [J].
Barker, SLR ;
Shortreed, MR ;
Kopelman, R .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :990-995
[10]  
BARKER SLR, 1996, SPIE INT SOC OPT P, V2836, P304